General characteristics ATL 100
ATL 100 is the smallest device of the ATL series. It is housed -in a 3 modular box. It is suitable for monitoring two independent power sources and to manage the switching between the two sources with a single phase control. The rated voltage value is selectable using a terminals bypass between 110VAC and 230VAC and the response thresholds of min and max voltage are 80% and 120% of the rated value sat.
General characteristics ATL 600 - ATL 610
The automatic transfer switch controllers ATL 600 / ATL 610 are used for the automatic or manual switching of the load from the MAIN LINE to a stand-by or emergency SECONDARY LINE and vice versa. They have two outputs for the “automatic” and/or “manual” control of contactors or motorised circuit breakers and switches.
The main features are:
– Supply input
• Single in AC for ATL 600
• Dual in AC and DC for ATL 610
– Measurement inputs for three phase + neutral voltage values; also suitable for 1 and 2 phase lines
– 128x80 backlit graphic LCD to view measurements, events and alarms in 5 languages (English, Italian, French, Spanish and German)
– 2 status indication LEDs
– 6 programmable digital inputs
– 7 programmable relay outputs
– Viewing of L-L and L-N voltage values of the controlled lines
– Status viewing of contactor or motorised circuit breakers and switches
– Configuration programming of lines, control and supervision parameters for emergency demand of generating set
– Event logging
– Microprocessor supervision of functions; including virtual real time clock for ATL 610– Communication interface by front optical port with CX01 or CX02 dongle using USB or Wi-Fi
– Compatible with Synergy supervision and energy management software, Xpress remote control and configuration software and with the Sam1 application for Android/iOS
– Modbus-RTU, ASCII and TCP communication protocol
CONTROL FUNCTIONS OF THE LINES
– Phase sequence and phase loss
– Minimum and maximum voltage
– Voltage asymmetry
– Minimum and maximum frequency.
Operational characteristics ATL 600 - ATL 610
– Power supply
• Power supply voltage: 110...240VAC ; 12/24VDC only for ATL 610
• Voltage range: 90...264VAC; 9...36VDC only for ATL 610
– Voltage measurement inputs
• Rated voltage Ue: 100...480VAC (L-L)
• Measuring range: 50...576VAC (L-L)
• Frequency range: 45...65Hz.
– Programmable digital inputs
• Negative inputs
– Programmable relay outputs
• 5 each with 1 normally open contact (NO - SPST) rated 8A 250VAC
• 2 each with 1 changeover contact (NO/NC - SPDT) rated 8A 250VAC
– Enclosure
• Flush-mount housing: 144x144mm/5.7x5.7”
• IEC degree of protection: IP40 on front; IP65 with optional seal EXP80 01; IP20 at rear.
Supervision and energy management software Synergy See section 27.
Xpress configuration software and Sam1 application See section 27.
EXP expansion modules See page 28-2.
Certifications and compliance
Certifications pending: cULus for ATL 100 Certifications obtained: cULus (only for ATL 600 - ATL 610), EAC, RCM.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL508, CSA C22.2 n°14.