Skip to Main Content »

Search Site
Your shopping cart is empty

All Prices are in Canadian Dollars

Philips Bodine B50CRM - Emergency Ballast - 90 Min. - Operates (1) or (2) T5, T8, T9, T10, T12 Fluoresent Lamps - Universal Voltage 120-277V

Be the first to review this product

Bodine B50 Emergency Ballast Up to 1400Lumen, One 17-215 W (2‘-8’) or two 17-40 W (2’-4’) T8, T9, T10 or T12 lamps, or one 18-55 W or two 18-39 W (4-pin) long compacts. Provides AC output for one T5 or T8, DC output for one or two T8s, Low-profile design, Compatible with Philips InstantFit LED T8 retrofit lamps and others, Compatible with end-of-lamp-life circuitry. 120-277VAC.

 

Availability: In stock

$183.89

Philips Bodine B50CRM - Emergency Ballast - 90 Min. - Operates (1) or (2) T5, T8, T9, T10, T12 Fluoresent Lamps - Universal Voltage 120-277V

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code B50CRM
Brand Philips
Family CSA Certified Emergency Lighting Equipment
Part No 498097
Length (in) 13.31" (338.1mm)
Width (in) 2.2" (55.88mm)
Height (in) 1.18" (29.97mm)
Voltage (V) 120-277V, 50/60Hz (120 Through 277VAC)
Input Current 60mA
Wattage (w) 5.0 Watts
Bulb Type Fluorescent Lamps
Switch Type: Test Switch: Single Pole
Lumens (Initial) 1600 Lumens
Battery Back Up Yes
Battery Type: High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy
Recharge Time: 24 Hrs
Max. Charge Current 180mA
Operates One 16-40 W (2’-4’) T8, T9, T10 or T12 (including T12 HO) lamp; or one 18-39 W rapid-start long compact.
Start Temp. (Min) 0°C (32°F)
Start Temp. (Max) 50°C (122°F)
Weight (lb.) 2.7 lbs
UL Listed UL, CSA and Code Compliance
Case Quantity 1
Warranty 5 Years (NOT pro-rata)

APPLICATION

The B50 emergency ballast works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The emergency ballast handles a wide range of input voltages and frequencies and consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry in one compact galvanized metal case. The B50 can be used with one or two T8,T9,T10,T12 fluorescent lamps. It operates one 22 - 55 W (2' - 4') T5 lamp, and also including standard, energy saving, HO, VHO, circline, U-shaped and rapid-start (4-pin) long compact fluorescent lamps. Also operates one 8.5 - 16.5W Philips LED T8 InstantFit lamp: 9290002840, 9290002841, 9290002842, 9290002862, 9290002880, 9290002881, 9290002882, 9290002883, 9290011183, 9290011184, 9290011185, 9290011186, 9290011179, 9290011180, 9290011181, 9290011182. One- or two-lamp operation may be selected (see Table 1). It is also compatible with most single- and multi-lamp electronic and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B50 is suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations. It is not suitable for air handling heated air outlets or wet or hazardous locations. For information about specific lamp and ballast compatibility, please call the factory. Recommended applications include: international line voltages from 120 through 277 VAC (50 or 60 Hz); drilling rigs where generators are the primary source of power; and other applications requiring higher tolerance of line voltage variation or harmonic distortion.

OPERATION

When AC power fails, the B50 immediately switches to the emergency mode, operating either one or two lamps at a reduced lumen output for a minimum of 90 minutes. When the AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.

INSTALLATION

The B50 does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B50 may be installed inside, on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 5°C.

EMERGENCY ILLUMINATION

Depending on the number (one or two), wattage and type of lamps selected, the B50 produces up to 1600 lumens initial emergency light output (see Table 2). If two-lamp operation is selected, light output is evenly divided between the lamps for better distribution of emergency illumination.


B50 / B50CRM / B50-CAN

CSA Certified Emergency Lighting Equipment


2014 Upgrade: Available in October
LowProfile AC and DC output for T5 and T8 Lamps compatibility

One- or two-lamp operation; Universal input voltage; 
End-of-lamp-life compatible 

Product Summary

  • UL Listed for US and Canada
    Factory or Field Installation
    (Indoor and Damp)
  • Illumination Time
    90 Minutes
  • Initial Light Output
    Up to 1600 Lumens
  • Full Warranty
    5 Years (NOT pro-rata)
  • Voltage
    120 Through 277 VAC, 50 or 60 Hz
  • AC Input Current
    60 mA
  • AC Input Power Rating
    5.0 Watts
  • Test Switch
    2W-ITS (2-wire Illuminated Test Switch)
  • Battery
    High-Temperature, Maintenance-Free
    Nickel-Cadmium Battery
    7- to 10-Year Life Expectancy
  • Battery Charging Current
    180 mA
  • Recharge Time
    24 Hour
  • Charging Indicator Light
    LED
  • Temperature Rating (Ambient)
    0°C to +50°C (32°F to 122°F)
  • Dimensions
    13.31” x 2.2” x 1.18”
    (338.1 mm x 55.88 mm x 29.97 mm)
    Mounting Center 12.8” (325 mm)
  • Weight
    2.7 lbs. (1.26 kg)

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.