Emergency Fluorescent Ballasts
-
Bodine LP600M - Emergency Ballast - 90 Min. - Operates (1) x 14-54W T5 or (1) x 17-55W T8 or (1) x 36-55W 4-Pin CFL - 120/277V
LP600 / LP600M (Galvanized Metal Case), Flourescent Emergency Ballast, Low-Profile for Space-Limited Fixtiures, For Standard and High Output T5 and T8 Lamps. End-of-Lamp-Life Compatible and Compatible with TLED lamps.
When AC power fails, the LP600 immediately switches to the emergency mode, operating one lamp at high lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of AC ballast end-of-lamp-life shutdown circuits.
Learn More...$246.29 -
Philips Bodine B50 Cold-Pak - Emergency Ballast - 90 Min. Cold Environment Applications -20°C to 55°C Temperature Rating One- or Two-lamp Operation - 120-277 VAC - 60Hz
Philips Bodine B50 Cold-Pak - Emergency Ballast - 90 Min. Cold Environment Applications -20°C to 55°C Temperature Rating One- or Two-lamp Operation - 120-277 VAC - 60Hz - Up to 1200 Lumens @ 25°C - Single Pole Test Switch
Learn More...$263.88 -
TCP 20LP600 - Emergency Ballast - 90 Min. - Operates (1) T5, T8, T12 Fluoresent Lamps - Dual Voltage 120/277V - Damp Location - 1300 Lumens
TCP - Emergency Ballast - 90 Min. - Operates (1) T5, T8, T12 Fluoresent Lamps - Dual Voltage 120/277V - Damp Location - 1300 Lumens
Learn More...$201.19 -
TCP 20B30 - Emergency Ballast - 90 Min. - Operates (1) or (2) T5, T8, T12 Fluoresent Lamps - Dual Voltage 120/277V - Damp Location - 3000 Lumens
TCP - Emergency Ballast - 90 Min. - Operates (1) or (2) T5, T8, T12 Fluoresent Lamps - Dual Voltage 120/277V - Damp Location - 3000 Lumens
Learn More...$254.74 -
Philips Bodine B94CGU - Emergency Backup Ballast - 90 Min. - Operates (1) 18-42W 4-pin CFL Lamp - Universal Voltage 120-277 Volt
The B94CGU can be used with one 18 - 42 W (4-pin) twin, quad or triple twin-tube compact. It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B94CGU is suitable for indoor and damp locations.
When AC power fails, the B94CGU immediately switches to the emergency mode, operating one lamp at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.
Learn More...$214.09 As low as: $199.00 -
Philips Bodine B50LP - Emergency Ballast - 90 Min. - Operates (1) or (2) T8, T9, T10, T12 Fluoresent Lamps - Dual Voltage 120/277V
The B50LP can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving fluorescent lamps. One- or two-lamp operation may be selected (see Table 1). It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary
When AC power fails, the B50LP automatically switches to emergency power, operating one or two lamps at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.
Learn More...$219.99 -
Philips Bodine B50-CAN - Emergency Ballast - 90 Min. - Operates (1) or (2) T5, T8, T9, T10, T12 Fluoresent Lamps - Dual Voltage 120/347V
The B50-CAN can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving. One- or two-lamp operation may be selected (see Table 1). It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts.
When AC power fails, the B50-CAN immediately switches to the emergency mode, operating either one or two lamps at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the B50-CAN automatically returns to the charging mode
Learn More...$292.88