  1. TCP 20760C - White Polycarbonate 2 x 6 Volt  5.4 Watt Emergency Light - Square Heads - 120/277 Volt Input - UL & cUL Listed

    TCP 20760C - White Polycarbonate 2 x 6 Volt 5.4 Watt Emergency Light - Square Heads - 120/277 Volt Input - UL & cUL Listed

    TCP 20760(C) unit is a completely self-contained emergency light which is made for use on 120 or 277 volt circuits. A 6V maintenance free, sealed lead acid battery is included with the unit, which will provide 10 watts for 30 minutes of emergency lighting. Back Side Hardwire Mounting Only, No External Wire or Plug.


    Learn More...
    $55.00
    Ships free

  2. Bodine 197517 B33 - Parallel Emergency Ballast - 90 Min. - Operates (2) or (3) 32W 4Ft T8 Fluoresent Lamps - 120/277V

    Bodine 197517 B33 - Parallel Emergency Ballast - 90 Min. - Operates (2) or (3) 32W 4Ft T8 Fluoresent Lamps - 120/277V

    The B33 can be used with two or three 32 W (4’) T8 fluorescent lamps without integral starters. It is compatible ONLY with instant start, parallel two-, three- or four-lamp electronic or standard AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B33 is suitable for indoor and damp locations.

    When AC power fails, the B33 immediately switches to the emergency mode, operating either two or three lamps for a minimum of 90 minutes. When AC power is restored, the B33 automatically returns to the charging mode.


    Learn More...
    $556.75
    Ships free

  3. Bodine 217000 LP600M - Emergency Ballast - 90 Min. - Operates (1) x 14-54W T5 or (1) x 17-55W T8 or (1) x 36-55W 4-Pin CFL - 120/277V

    Bodine 217000 LP600M - Emergency Ballast - 90 Min. - Operates (1) x 14-54W T5 or (1) x 17-55W T8 or (1) x 36-55W 4-Pin CFL - 120/277V

    LP600 / LP600M (Galvanized Metal Case), Flourescent Emergency Ballast, Low-Profile for Space-Limited Fixtiures, For Standard and High Output T5 and T8 Lamps. End-of-Lamp-Life Compatible and Compatible with TLED lamps. 

    When AC power fails, the LP600 immediately switches to the emergency mode, operating one lamp at high lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of AC ballast end-of-lamp-life shutdown circuits.


    Learn More...
    $234.70
    Ships free

  4. Bodine B50LP - Emergency Ballast - 90 Min. - Operates (1) or (2) T8, T9, T10, T12 Fluoresent Lamps - Dual Voltage 120/277V

    Bodine B50LP - Emergency Ballast - 90 Min. - Operates (1) or (2) T8, T9, T10, T12 Fluoresent Lamps - Dual Voltage 120/277V

    The B50LP can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving fluorescent lamps. One- or two-lamp operation may be selected (see Table 1). It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary

    When AC power fails, the B50LP automatically switches to emergency power, operating one or two lamps at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.


    Learn More...
    $219.99
    Ships free

  5. Bodine 197921 B100ELC - Emergency Ballast - 90 Min. - Operates (1) x 32-40W T8, T10, T12 or PLL CFL - 120V

    Bodine 197921 B100ELC - Emergency Ballast - 90 Min. - Operates (1) x 32-40W T8, T10, T12 or PLL CFL - 120V

    B100 available only as as ELC (end-of-lamp-life compatible). One 17-215 W (2’- 8’) T8, T10 or T12 lamp or one (4-pin) long compact. Not recommended with reduced-wattage, energy-saving T8 lamps.

    When AC power fails, the B100 immediately switches to the emergency mode, operating one lamp at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.


    Learn More...
    $82.00
    Ships free