Skip to Main Content »

Search Site
Your shopping cart is empty

All Prices are in Canadian Dollars

Solid State Components

Items 1 to 20 of 223 total
  1. ALLTEMP 24-ICM325HNVC-LF - Head Pressure Controls - Dual ON/ OFF Delays Control Fan - 120-600VAC

  2. ALLTEMP 24-ICM326HN - Head Pressure Controls - Dual ON/ OFF Delays Control Fan - 120 or 208/ 240 VAC

  3. ALLTEMP 24-ICM6100 - Fan Coil Relay Controls - Fan safety alarm circuit - 24VAC Input

    ALLTEMP 24-ICM6100 - Fan Coil Relay Controls - Fan safety alarm circuit - 24VAC Input

    ALLTEMP 24-ICM6100 - Fan Coil Relay Controls - Fan safety alarm circuit - 24VAC Input
    Learn More...
    $416.13

  4. ALLTEMP 24-ICM6200 - Fan Coil Relay Controls - 20/24 VAC power supply - Suitable for 1/8 HP motors

    ALLTEMP 24-ICM6200 - Fan Coil Relay Controls - 20/24 VAC power supply - Suitable for 1/8 HP motors

    ALLTEMP 24-ICM6200 - Fan Coil Relay Controls - 20/24 VAC power supply - Suitable for 1/8 HP motors
    Learn More...
    $255.07

  5. ALLTEMP 24-ICM6201 - Fan Coil Relay Controls - 20/24 VAC power supply - Suitable for 1/8 HP motors

  6. ALLTEMP 24-UMSR50 - Universal Motor Starting Relay - 110-270 VAC, Single Phase - Up to 10 HP

    ALLTEMP 24-UMSR50 - Universal Motor Starting Relay - 110-270 VAC, Single Phase - Up to 10 HP

    Universal Motor Starting Relay - 110-270 VAC, Single Phase - Up to 10 HP - 50A Switching Capabilities.


    Learn More...
    $70.86

  7. ALLTEMP 24-ICM289 - Fan Blower Controls

    ALLTEMP 24-ICM289 - Fan Blower Controls

    ICM Controls ICM289 Furnace Control Replacement for Lennox Control Boards, Replaces All BCC1, BCC2 and BCC3 Circuit Boards

    Voltage Range: Line (98 to 132 VAC) @ 60 Hz

    Cool Blower: 20A @ 120 VAC

    Heat Blower: 20A @ 120 VAC

    Inducer Motor: 5A @ 120 VAC

    Cool Blower On Delay: 1 second

    Cool Blower Off Delay: 1 second

    Heat Blower On Delay: 45 seconds

    Heat Blower Off Delay: 90, 150, 210, 270 seconds


    Learn More...
    $417.14

  8. ALLTEMP 24-ICM288 - Fan Blower Controls

    ALLTEMP 24-ICM288 - Fan Blower Controls

    Voltage Range: Line 98-132 VAC @ 60HZ

    Ignitor: 5A, 120 VAC

    Cool Blower: 10A, 2HP, 240 VAC

    Heat: 5A, 1/2 HP, 250 VAC

    Inducer Blower: 4A, 120 VAC

    Gas Valve: 1A, 24 VAC

    Humidifier Motor: 0.5A, 24 VAC

    Electronic Air Cleaner: 1A, 120 VAC


    Learn More...
    $464.29

  9. ALLTEMP 24-ICM287 - Fan Blower Controls

    ALLTEMP 24-ICM287 - Fan Blower Controls

    Line Voltage: 120 VAC @ 60 Hz

    Control Voltage: 24 VAC @ 60Hz

    Heat Blower: 10A @ 120 VAC

    Cool Blower: 30A @ 120 VAC

    Inducer Motor: 30A, 120 VAC


    Learn More...
    $221.84

  10. ALLTEMP 24-ICM286 - Fan Blower Controls

    ALLTEMP 24-ICM286 - Fan Blower Controls

    • Voltage Range: Line (98-132 VAC) @ 60Hz
    • Cool Blower: 30A, 2 HP, 240 VAC
    • Heat: 20A, 240 VAC
    • Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
    • Ignitor: 10A FLA @ 120 VAC
    • Humidifier: 5 amps @ 120 VAC
    • Electric Air Cleaner: 5 amps @ 120 VAC
    • Trial for Ignition: 7 seconds
    • Pre-purge Time: 15 seconds
    • Ignitor Warm Up Time: 7 seconds
    • Post-Purge Time: 15 seconds
    • Total Trials for Ignition: 3 (auto rest after 1 hour)
    • Heat Blower On: 30 seconds
    • Heat Blower Off: Selectable 90/120/150/180 seconds
    • Fan (Heat) On/Off Delay: 1 second
    • Cool On: 5 seconds
    • Cool Off: 45 seconds

    Learn More...
    $133.97

  11. ALLTEMP 24-ICM292 - Fan Blower Controls

    ALLTEMP 24-ICM292 - Fan Blower Controls

    Control Voltage: 24 VAC (18-30 VAC), 60Hz

    Line Voltage: 115/23 VAC, 60Hz

    Power Consumption: 03A plus gas valve curreny @ 24 VAC

    Operating Temperature: -40°C(-40°F) to 75°C(176°F)

    Timing:

    • Pre-purge: 20 seconds
    • Trial for Ignition: 6.5 seconds
    • Number of Trials: 4 (2+2, 3 minutes apart)
    • Lockout: 1 Hour
    • Post-purge: dip switch selectable 90, 120, 160, 180 seconds apart

    Inputs:

    • Power: SEC and COM
    • Thermostat Interface: R, W, Y and G
    • Safety Switches: Limit and Vent
    • Combustion Motor Hall Effect Sensor
    • Flame Sensing

    Outputs:

    • Spark
    • Gas Valve: GV
    • Induced Draft Motor
    • Multi speed indoor blower motor
    • Humidifier

    LED Indicators:

    • PWR(green): Steady ON - power to the board
    • OK(green): Steady ON - no fault
    • Flashing - fault code
    • Flame(yellow): Steady On - flame sensed, flashing two times -flame out of sequence

     


    Learn More...
    $479.65

  12. ALLTEMP 24-ICM2801 - Fan Blower Controls

    ALLTEMP 24-ICM2801 - Fan Blower Controls

    ALLTEMP 24-ICM2801 - Fan Blower Controls
    Learn More...
    $487.12

  13. ALLTEMP 24-ICM2804 - Fan Blower Controls - Low cost form, fit and functional replacement for Carrier: CES0110074-01

    ALLTEMP 24-ICM2804 - Fan Blower Controls - Low cost form, fit and functional replacement for Carrier: CES0110074-01

    Fan Blower Controls - Low cost form, fit and functional replacement for Carrier: CES0110074-01
    Learn More...
    $397.28

  14. ALLTEMP 24-ICM2805A - Fan Blower Controls - Low cost form, fit and functional OEM replacement control board for Nordyne: 903106-Kit

    ALLTEMP 24-ICM2805A - Fan Blower Controls - Low cost form, fit and functional OEM replacement control board for Nordyne: 903106-Kit

    Line Voltage Range: 120/240 VAC @ 60 Hz; Ignitor: 5A, 120 VAC; Cool Blower: 10A, 2HP, 240 VAC; Heat: 5A, 1/2 HP, 250 VAC; Inducer Blower: 4A, 120 VAC; Gas Valve: 1A, 24 VAC; Humidifier Motor: 0.5A, 24 VAC; Electronic Air Cleaner: 1A, 120 VAC


    Learn More...
    $370.27

  15. ALLTEMP 24-ICM2807 - Fan Blower Controls - Operating: -40°F to 176°F

  16. ALLTEMP 24-ICM2808 - Fan Blower Controls - Replacement for the York S1-331-03010000 and S1-331-02956000 furnace control boards - 18-30VAC

    ALLTEMP 24-ICM2808 - Fan Blower Controls - Replacement for the York S1-331-03010000 and S1-331-02956000 furnace control boards - 18-30VAC

    Fan Blower Controls - Replacement for the York S1-331-03010000 and S1-331-02956000 furnace control boards - 18-30VAC


    Learn More...
    $274.78

  17. ALLTEMP 24-ICM291 - Fan Blower Controls

    ALLTEMP 24-ICM291 - Fan Blower Controls

    Control Voltage: 24 VAC (18-30 VAC), 60Hz

    Line Voltage: 208/230 VAC, 60Hz

    Power Consumption: 03A plus gas valve current @ 24 VAC

    Operating Temperature: -40°C(-40°F) to 75°C(176°F)

    Timing:

    • Pre-purge: 45 seconds
    • Trial for Ignition: 5+2 seconds
    • Retry Period: every 20 seconds for 15 minutes
    • Lockout: manual reset
    • Post-purge: 45 seconds

    Inputs:

    • Power: RT and C
    • Thermostat Interface: R, W and G
    • Safety Switches: RS, LS and CS
    • Combustion Motor Hall Effect Sensor
    • Flame Sensing

    Outputs:

    • Spark
    • Gas Valve: GV
    • Combustion Motor: BM
    • Indoor Fan Motor: IFO

    LED Indicators:

    • Red LED: Steady ON - Normal operation Flashing - Fault codes

     


    Learn More...
    $644.18

  18. ALLTEMP 24-ICM284 - Fan Blower Controls - Microprocessor based

    ALLTEMP 24-ICM284 - Fan Blower Controls - Microprocessor based

    Line Voltage: 208 VAC @ 60 Hz

    Ignitor: 5A resistive @ 208 VAC

    Cool Blower: 30A, 2HP @ 240 VAC

    Heat Blower: 10A, .5HP @ 250 VAC

    Inducer Motor: 4A, 120 VAC

    Gas Valve: 4A @ 24 VAC

    Compressor: 5A resistive @ 24 VAC


    Learn More...
    $684.32

  19. ALLTEMP 24-ICM282A - Fan Blower Controls - direct replacement for Carrier HK42FZ004/007/008/009/011/013/016

    ALLTEMP 24-ICM282A - Fan Blower Controls - direct replacement for Carrier HK42FZ004/007/008/009/011/013/016

    Voltage Range: Line (98 to 132 VAC) @ 60Hz

    Cool Blower: 10A, 2 HP, 240 VAC

    Heat: 5A, 1/2 HP, 240 VAC

    Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC

    Gas Valve: 1.5A @ 30 VAC

    Heat Blower On: 60 seconds

    Heat Blower Off: 90, 120, 150, and 180 sec

    Fan (Heat) On/Off: 1-second

    Cool On: 2 seconds

    Cool Off: 90 seconds with jumper JW2 uncut; 5 seconds with jumper JW2 cut


    Learn More...
    $674.80

  20. ALLTEMP 24-ICM281 - Fan Blower Controls - direct replacement board for Carrier CESO11005700/01/02

    ALLTEMP 24-ICM281 - Fan Blower Controls - direct replacement board for Carrier CESO11005700/01/02

    Voltage Range: Line (98 to 132 VAC) @ 60Hz

    Cool Blower: 10A, 2 HP, 240 VAC

    Heat: 5A, 1/2 HP, 240 VAC

    Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC

    Gas Valve: 1.5A @ 30 VAC

    Heat Blower on Delay: 40 seconds

    Heat Blower Off Delays: 90, 135, 180, and 225 seconds

    Fan (Low) On/Off: 1-second

    Cool Blower on Delay: 5 seconds

    Cool Blower Off Delay: 90 seconds


    Learn More...
    $426.19

Items 1 to 20 of 223 total