Fan Blower Controls
-
ALLTEMP 24-ICM273 - Fan Blower Controls
Voltage Range: 18-30 VAC
Output: 2 amps @ 240 VAC
Time Delays:- Blower OFF delay: 60 seconds
$52.43 -
ALLTEMP 24-ICM255 - Fan Blower Controls
Voltage:18-30VAC
N.O.: 20 Amps @ 240VAC
N.C.: 20 amps @ 240VAC
Time Delays Fixed
On - 1 second
Off - 60 seconds
Dimensions: 2.5"×2.5"
Learn More...$64.42 -
ALLTEMP 24-ICM253 - Fan Blower Controls
Voltage:18-30VAC
1 Amp Max
40 mA Min.
10 Amp Inrush
Adjustable time delay 12-390 seconds
Dimensions: 2"×3"
Learn More...$66.64 -
ALLTEMP 24-ICM254 - Fan Blower Controls
Voltage:18-30VAC; 1 Amp Max; 40 mA Min. ; 10 Amp Inrush; Time Delays Adjustable; On - 1-180 seconds; Off - 12-390 seconds; Dimensions: 2"×3"
Learn More...$86.54 -
ALLTEMP 24-ICM286 - Fan Blower Controls
- Voltage Range: Line (98-132 VAC) @ 60Hz
- Cool Blower: 30A, 2 HP, 240 VAC
- Heat: 20A, 240 VAC
- Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
- Ignitor: 10A FLA @ 120 VAC
- Humidifier: 5 amps @ 120 VAC
- Electric Air Cleaner: 5 amps @ 120 VAC
- Trial for Ignition: 7 seconds
- Pre-purge Time: 15 seconds
- Ignitor Warm Up Time: 7 seconds
- Post-Purge Time: 15 seconds
- Total Trials for Ignition: 3 (auto rest after 1 hour)
- Heat Blower On: 30 seconds
- Heat Blower Off: Selectable 90/120/150/180 seconds
- Fan (Heat) On/Off Delay: 1 second
- Cool On: 5 seconds
- Cool Off: 45 seconds
$133.97 -
ALLTEMP 24-ICM274 - Fan Blower Controls
Voltage Range: 18-30 VAC
Learn More...
Contact Ratings:
Y out: 1.5 amps
Fan: 2 amps
Elec. Heat Relay: 30 amps @ 240 VAC
Time Delays: Blower OFF delay: 60-240 seconds$153.22 -
ALLTEMP 24-ICM276 - Fan Blower Controls
Voltage Range: 18-30 VAC
Contact Ratings:
- Fan: 20 amps @ 240 VAC
- Inducer Fan: 2 amps
Time Delays:
- Heat ON delay: 60 Seconds
- Heat OFF delay: 120,150,180 seconds
- Cool OFF delay: 90 seconds
$157.92 -
ALLTEMP 24-ICM270 - Fan Blower Controls
Voltage Range: 18-30 VAC
Contact Ratings: Heat/cool speed
- N.O.: 20 amps @ 240 VAC
- N.C.: 10 amps @ 240 VAC
Time Delays:
- Blower ON delay: 30 Seconds
- Blower OFF delay: 90,120,150,180 seconds
$161.34 -
ALLTEMP 24-ICM271 - Fan Blower Controls
Voltage Range: 18-30 VAC
Contact Ratings:
- N.O.: 20 amps
- N.C.: 10 amps
Time Delays:
- Heat ON delay: 75 Seconds
- Heat OFF delay: 105 seconds
- Cool OFF delay: 90 seconds
$192.38 -
ALLTEMP 24-ICM277 - Fan Blower Controls
Voltage Range: 18-30 VAC
Contact Ratings: Heat/cool speed
- N.O.: 20 amps
- N.C.: 10 amps
Time Delays: Blower ON delay: 7 Seconds
- Blower OFF delay: 65 seconds
$205.28 -
ALLTEMP 24-ICM287 - Fan Blower Controls
Line Voltage: 120 VAC @ 60 Hz
Control Voltage: 24 VAC @ 60Hz
Heat Blower: 10A @ 120 VAC
Cool Blower: 30A @ 120 VAC
Inducer Motor: 30A, 120 VAC
Learn More...$221.84 -
ALLTEMP 24-ICM278 - Fan Blower Controls
Terminals: - 120/240 VAC: N1-N5, S1-S5, H, L, L1, D1 - 18-30 VAC: Y, G, W, C, R, W2, X, HL, PS1, PS2
Operating Temperature: 40ºF to +176ºF
Time Delays: - Heat ON: 60 Seconds - Heat OFF: 60-200 Seconds - Cool OFF: 40 Seconds
Learn More...$260.19 -
ALLTEMP 24-ICM275 - Fan Blower Controls
Voltage Range: 18-30 VAC
Contact Ratings:
- High: 20 amps @ 240 VAC
- Low: 10 amps @ 240 VAC
Time Delays:
- Heat ON delay: 60 Seconds
- Heat OFF delay: 60-240 seconds
- Cool OFF delay: 90 seconds
$270.94 -
ALLTEMP 24-ICM2808 - Fan Blower Controls - Replacement for the York S1-331-03010000 and S1-331-02956000 furnace control boards - 18-30VAC
Fan Blower Controls - Replacement for the York S1-331-03010000 and S1-331-02956000 furnace control boards - 18-30VAC
Learn More...$274.78 -
ALLTEMP 24-ICM2805A - Fan Blower Controls - Low cost form, fit and functional OEM replacement control board for Nordyne: 903106-Kit
Line Voltage Range: 120/240 VAC @ 60 Hz; Ignitor: 5A, 120 VAC; Cool Blower: 10A, 2HP, 240 VAC; Heat: 5A, 1/2 HP, 250 VAC; Inducer Blower: 4A, 120 VAC; Gas Valve: 1A, 24 VAC; Humidifier Motor: 0.5A, 24 VAC; Electronic Air Cleaner: 1A, 120 VAC
Learn More...$370.27 -
ALLTEMP 24-ICM280 - Fan Blower Controls - direct replacement board for Goodman, Janitrol, TI, White-Rodgers and UTEC
- Voltage Range: Line (98 to 132 VAC) @ 60Hz
- Cool Blower: 10A, 2 HP, 240 VAC
- Heat: 5A, 240 VAC
- Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
- Gas Valve: 1.5A @ 30 VAC
- Heat Blower on Delay: 30 seconds
- Heat Blower Off Delays: 90, 120 and 150 sec
- Cool Blower on Delay: 5 seconds
- Cool Blower Off Delay: 60 seconds
$384.62 -
ALLTEMP 24-ICM2804 - Fan Blower Controls - Low cost form, fit and functional replacement for Carrier: CES0110074-01
Fan Blower Controls - Low cost form, fit and functional replacement for Carrier: CES0110074-01 Learn More...$397.28 -
ALLTEMP 24-ICM289 - Fan Blower Controls
ICM Controls ICM289 Furnace Control Replacement for Lennox Control Boards, Replaces All BCC1, BCC2 and BCC3 Circuit Boards
Voltage Range: Line (98 to 132 VAC) @ 60 Hz
Cool Blower: 20A @ 120 VAC
Heat Blower: 20A @ 120 VAC
Inducer Motor: 5A @ 120 VAC
Cool Blower On Delay: 1 second
Cool Blower Off Delay: 1 second
Heat Blower On Delay: 45 seconds
Heat Blower Off Delay: 90, 150, 210, 270 seconds
Learn More...$417.14 -
ALLTEMP 24-ICM281 - Fan Blower Controls - direct replacement board for Carrier CESO11005700/01/02
Voltage Range: Line (98 to 132 VAC) @ 60Hz
Cool Blower: 10A, 2 HP, 240 VAC
Heat: 5A, 1/2 HP, 240 VAC
Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
Gas Valve: 1.5A @ 30 VAC
Heat Blower on Delay: 40 seconds
Heat Blower Off Delays: 90, 135, 180, and 225 seconds
Fan (Low) On/Off: 1-second
Cool Blower on Delay: 5 seconds
Cool Blower Off Delay: 90 seconds
Learn More...$426.19 -
ALLTEMP 24-ICM288 - Fan Blower Controls
Voltage Range: Line 98-132 VAC @ 60HZ
Ignitor: 5A, 120 VAC
Cool Blower: 10A, 2HP, 240 VAC
Heat: 5A, 1/2 HP, 250 VAC
Inducer Blower: 4A, 120 VAC
Gas Valve: 1A, 24 VAC
Humidifier Motor: 0.5A, 24 VAC
Electronic Air Cleaner: 1A, 120 VAC
Learn More...$464.29