Fan Blower Controls
-
ALLTEMP 24-ICM288 - Fan Blower Controls
Voltage Range: Line 98-132 VAC @ 60HZ
Ignitor: 5A, 120 VAC
Cool Blower: 10A, 2HP, 240 VAC
Heat: 5A, 1/2 HP, 250 VAC
Inducer Blower: 4A, 120 VAC
Gas Valve: 1A, 24 VAC
Humidifier Motor: 0.5A, 24 VAC
Electronic Air Cleaner: 1A, 120 VAC
Learn More...$464.29 -
ALLTEMP 24-ICM289 - Fan Blower Controls
ICM Controls ICM289 Furnace Control Replacement for Lennox Control Boards, Replaces All BCC1, BCC2 and BCC3 Circuit Boards
Voltage Range: Line (98 to 132 VAC) @ 60 Hz
Cool Blower: 20A @ 120 VAC
Heat Blower: 20A @ 120 VAC
Inducer Motor: 5A @ 120 VAC
Cool Blower On Delay: 1 second
Cool Blower Off Delay: 1 second
Heat Blower On Delay: 45 seconds
Heat Blower Off Delay: 90, 150, 210, 270 seconds
Learn More...$417.14 -
ALLTEMP 24-ICM292 - Fan Blower Controls
Control Voltage: 24 VAC (18-30 VAC), 60Hz
Line Voltage: 115/23 VAC, 60Hz
Power Consumption: 03A plus gas valve curreny @ 24 VAC
Operating Temperature: -40°C(-40°F) to 75°C(176°F)
Timing:
- Pre-purge: 20 seconds
- Trial for Ignition: 6.5 seconds
- Number of Trials: 4 (2+2, 3 minutes apart)
- Lockout: 1 Hour
- Post-purge: dip switch selectable 90, 120, 160, 180 seconds apart
Inputs:
- Power: SEC and COM
- Thermostat Interface: R, W, Y and G
- Safety Switches: Limit and Vent
- Combustion Motor Hall Effect Sensor
- Flame Sensing
Outputs:
- Spark
- Gas Valve: GV
- Induced Draft Motor
- Multi speed indoor blower motor
- Humidifier
LED Indicators:
- PWR(green): Steady ON - power to the board
- OK(green): Steady ON - no fault
- Flashing - fault code
- Flame(yellow): Steady On - flame sensed, flashing two times -flame out of sequence
$479.65 -
ALLTEMP 24-ICM2801 - Fan Blower Controls
ALLTEMP 24-ICM2801 - Fan Blower Controls Learn More...$487.12 -
ALLTEMP 24-ICM281 - Fan Blower Controls - direct replacement board for Carrier CESO11005700/01/02
Voltage Range: Line (98 to 132 VAC) @ 60Hz
Cool Blower: 10A, 2 HP, 240 VAC
Heat: 5A, 1/2 HP, 240 VAC
Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
Gas Valve: 1.5A @ 30 VAC
Heat Blower on Delay: 40 seconds
Heat Blower Off Delays: 90, 135, 180, and 225 seconds
Fan (Low) On/Off: 1-second
Cool Blower on Delay: 5 seconds
Cool Blower Off Delay: 90 seconds
Learn More...$426.19