Lovato PMA50A240 - PUMP PROTECTION RELAY FOR SINGLE AND THREE-PHASE SYSTEMS - MAXIMUM AC CURRENT AND MINIMUM COSΦ - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 5A OR 16A

Be the first to review this product

Lovato PMA50A240 - PUMP PROTECTION RELAY FOR SINGLE AND THREE-PHASE SYSTEMS - MAXIMUM AC CURRENT AND MINIMUM COSΦ - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 5A OR 16A

 

Availability: In stock

$496.03

Lovato PMA50A240 - PUMP PROTECTION RELAY FOR SINGLE AND THREE-PHASE SYSTEMS - MAXIMUM AC CURRENT AND MINIMUM COSΦ - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 5A OR 16A

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code PMA50A240
Brand Lovato
UPC 8013975172841
Voltage (V) 220...240VAC
Amperage 5/16A
Amp Rating 5/16A
Wattage (w)
Phase 3/1 Phase
UL Listed cULus,EAC
Notes HS Code: 85364900
Cross Refefence Conformity:
IEC/EN 60255-5
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CSA C22.2 n° 14

General characteristics

– Pump protection relay against dry running, auxiliary AC power supply
– Motor under-load and over-current control
– Direct connection up to 16A max or by current transformer (CT)
– Excellent tripping accuracy
– Voltage control range 80...660VAC
– Current control range 0.1...16A
– Resetting and enabling consent input
– 1 relay output relay with 1 changeover contact (SPDT)
– Modular DIN 43880 housing, 3 module
– IEC degree of protection: IP40 on front (only when placed in IP40 enclosure or control board); IP20 at terminals.

ADJUSTMENTS

"Cos min” Minimum costhreshold 0.1...0.99 (under-load/dry running)
“Imax” Maximum (over) current threshold 10...100%Ie
"Trip delay" Tripping time for minimum cosand maximum current 0.1...10s
“Inhibition time” Inhibition delay for external input or at power up 1...60s
“Aut. reset delay” Automatic reset time OFF...100min
“Mode” • Rated current 5A or 16A
• Single or three phase
• External reset On or Off.

Certifications and compliance

Certifications obtained: EAC; UL Listed, for USA and Canada (cULus - File E93601), as Auxiliary Devices - Modular ampere monitoring relays.
Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14.

 


Lovato PMV80NA600 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - MINIMUM AND MAXIMUM FREQUENCY - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 480...600VAC 50/60HZ
$784.30

Lovato PMV55A440 - VOLTAGE MONITORING RELAY FOR SINGLE-PHASE SYSTEM - MINIMUM AND MAXIMUM AC VOLTAGE - 380…440VAC 50/60HZ
$387.53

Lovato PMV95NA575NFC - Multifunction Protection Relay with NFC Technology & App - 3 Phase - Phase to Phase Control Voltage 380-575Vac - 1 Relay Output 8A 250Vac

$333.19

$289.08


Lovato PMF20A240 - FREQUENCY MONITORING RELAY FOR SINGLE AND THREE-PHASE SYSTEMS - MINIMUM AND MAXIMUM FREQUENCY - 220…240VAC 50/60HZ
$726.61

Lovato PMV20A240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 100…240VAC 50/60HZ

$271.30

$159.90


Lovato PMV70NA440 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS AND ASYMMETRY - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 380…575VAC 50/60HZ
$654.21

Lovato PMV80NA440 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - MINIMUM AND MAXIMUM FREQUENCY - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 380…575VAC 50/60HZ
$784.30

Lovato PMV60A600, Voltage Monitoring Realy for Three-phase System, Without Neutral, Minimum AC Voltage and Asymmetry. Phase Loss and Incorrect Phase Sequence, 600VAC 50/60Hz
$581.32