Skip to Main Content »

Search Site
Your shopping cart is empty

All Prices are in Canadian Dollars

Lovato PMV80NA240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - MINIMUM AND MAXIMUM FREQUENCY - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 208…240VAC 50/60HZ

Be the first to review this product

Lovato PMV80NA240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - MINIMUM AND MAXIMUM FREQUENCY - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 208…240VAC 50/60HZ

 

Availability: In stock

$784.30

Lovato PMV80NA240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - MINIMUM AND MAXIMUM FREQUENCY - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 208…240VAC 50/60HZ

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code PMV80NA240
Brand Lovato
UPC 8013975179840
Voltage (V) 208...240VAC
Wattage (w)
Phase Three Phase
UL Listed cULus
Notes HS Code: 85364900
Cross Refefence Conformity:
IEC/EN 60255-5
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CSA C22.2 n° 14

General characteristics

– Voltage monitoring relay, self powered, for minimum and maximum voltage, minimum and maximum frequency, phase loss, neutral loss and incorrect phase sequence
– 4 configurable rated voltage (Ue):
• PMV80N A240: 208-220-230-240VAC (phase-phase) 120-127-132-138VAC (phase-neutral)
• PMV80N A440: 380-400-415-440VAC (phase-phase) 220-230-240-254VAC (phase-neutral)
• PMV80N A600: 480-525-575-600VAC (phase-phase) 277-303-332-347VAC (phase-neutral)
– Excellent tripping accuracy
– TRMS measurements (True Root Mean Square)
– Phase loss detection if one of the voltages is <70% rated value
– Phase or neutral loss tripping time: 60ms
– 2 relay outputs, each with 1 changeover contact (SPDT)
– Modular DIN 43880, 3 module
– IEC degree of protection: IP40 on front (only when placed in iP40 enclosure or control board); IP20 at terminals.

ADJUSTMENTS

“V max” Maximum voltage tripping threshold 105...115% Ue
“V min” Minimum voltage tripping threshold 80...95% Ue
“Hz min/max” Minimum/maximum frequency tripping threshold 1...10%
“V delay” Tripping time 0.1...20s
“Hz delay” Tripping time 0.1...5s.

Certifications and compliance

Certifications obtained: EAC.
Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14.