Hammond 1182P110 - Toroid Power Transformer - 117/234 VAC Dual Primary - 50/60 Hz - 500VA

Be the first to review this product

Hammond 1182P110 - Toroid Power Transformer - 117/234 VAC Dual Primary - 50/60 Hz - 500VA - 220V C.T. @ 2.27A Secondary (RMS) Series - 110V @ 4.54A Secondary (RMS) Parallel

 

Availability: In stock

$186.19

Hammond 1182P110 - Toroid Power Transformer - 117/234 VAC  Dual Primary - 50/60 Hz - 500VA

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code 1182P110
Brand Hammond
Family Power Transformers
Height (in) 2.25''
Diameter (in) Outside Diameter: 5.5'', Inside Diameter: 2.3''
Power Rating (VA) 500VA
First Voltage 117/234 VAC, 50/60Hz
Secondary Voltage Series : 220V C.T. @ 2.27A; Parallel : 110V @ 4.54A
UPC 62398053183
Weight (lb.) 7.75 lbs
UL Listed CSA, CE, UL,RoHS
Case Quantity 1
Notes For additional options and special quantity discounts, please contact our sales department 1-(855)-296-9508 x 102 or send email to cs@bulbspro.com

Features

  • Torodial transformer benefits:
  • low profile
  • lightweight
  • cool running / high efficiency
  • due to the core shape - low stray magnetic flux leakage (low EMI)
  • Dual 117/234 VAC primary, 50/60 Hz. operation.
  • Note: Units are designed to have all windings engaged (either series or parallel connected) or connected as an autotransformer. Connection sheet included with transformer. See Product Resources for Download.
  • Supplied with two neoprene rubber insulating pads, one metal centering washer and all mounting hardware (except the 1,500 VA size).
  • 1,500 VA size - is supplied with a potted center for extra strength.
  • Minimum 8" long flexible leads
  • Manufactured using Class B (130 degree C) materials.
  • Hi-Pot test of 4,000VAC RMS between primary & secondary
  • UL recognized to UL506 (XPTQ2.Guide) UL file #E207860
  • CSA certified to C22.2 #66 - CSA file #209651
  • CE compliant to IEC 61558-2-4
  • This series replaces our older 182 Toroid Series.
  • Note about Inrush Current: 

    Due to the superior magnetic properties of Toroidal transformers they will be susceptible to high magnetizing current when initially energized, only limited by the low DC resistance of the primary winding. Depending on where you are in the AC cycle when the transformer is energized dictates the chances of overloading the supply circuit. This is why the transformer may sometimes energize without a problem and other times it will blow the fuse or trip the circuit breaker. The duration of this overload is rarely longer than a half of a cycle. Therefore, you should consider using a slow-blow fuse, time delayed circuit breaker or other form of soft start circuitry for the supply line when using these high efficient Toroidal transformers.