Safety
-
Occupational
Safety & Health Goods
-
Audible Signals
Safety & Health Goods
-
Visual Signals
Safety & Health Goods
-
Hazardous Location Signals
Safety & Health Goods
-
Caution Tape
Safety & Health Goods
-
Fire Protection Equipment
Safety & Health Goods
-
Pushbuttons
Safety & Health Goods
-
Utility Boxes
Safety & Health Goods
-
Clocks
Safety & Health Goods
-
Magnetic Switches
Safety & Health Goods
-
Automatic Door Operator
Safety & Health Goods
-
Lockout Tagout
Safety & Health Goods
-
Maple Armor Firewatcher Panel 105 - 1 Addressable Signalling Line Circuit of 252 Addressable Devices - Wall Mount - Black Color - 120/240V
Expandable Black Color Addressable Panel 252 points 1 AMI, 1 MFU(4 NACs, 1 SLC, 4 Relays, 1 Class X network, 1 Class B network), 1 PCU, 1 LDU, Enclosure, Internal & External door with pictograms. Learn More...Call for price
Out of stock
-
Maple Armor Firewatcher Panel 106 - Supports up to 4 Addressable Signalling Line Circuits of 252 Addressable Devices/Points per Loop - Wall Mount - Red Color - 120/240V
Expandable Red Color Addressable Panel 252 to 1008 points 1 AMI, 1 to 5 NOU, 1 to 4 ALU, 1 ROU, 0 to 1 XNU, 1 PCU, 1 PTU, Enclosure, Internal & External door with English Silkscreen Learn More...Call for price
Out of stock
-
Maple Armor Firewatcher Panel 106S - 1 Addressable Signalling Line Circuits of 252 addressable devices/points - Wall Mount - Red Color - 120/240V
Compact 1-Loop Red Color Addressable Panel 252 points 1 AMI, 1 to 2 NOU, 1 ALU, 1 ROU, 0 to 1 XNU, 1 PCU, 1 PTU, Enclosure, Internal & External door with English Silkscreen Learn More...Call for price
Out of stock
-
Maple Armor Addressable NAC Booster FW131 - 8 Notification Appliance Circuits and 4 Form C dry Relay Contacts - Wall Mount - Red Color - 120/240V
FW131 supports 2 communication types: via SLC and Pass Through. It also has a capacity 8 Notification Appliance Circuits and 4 form C dry relay contacts (4 relays are used for indicating general loop/system troubles). The FW131 has a 4’’ LCD with 128 X 32 resolution, 4 navigation buttons and 1 enter button, and 4 LED indicators making it a highly intuitive fire alarm user interface. It will take up 9 addresses on the SLC loop. Learn More...Call for price
Out of stock
-
Maple Armor FW201AMI - Advance Machine Interface - 7” LCD Module - 11 Silicone Buttons - One Buzzer - 24Vdc
The electronic card FW201 is a subassembly of models FW106 FACP. It integrates two PCBA cards, a 7” LCD module, 11 silicone buttons, and a buzzer. Learn More...Call for price
Out of stock
-
Maple Armor FW327 Addressable Loop Unit - Supports Up to 252 Addressable Devices - 24Vdc
The module FW327 is a subassembly for the FW106/FW106S FACP (Fire Alarm Control Panel). The ALU supports one addressable loop circuit, which supports up to 252 addressable devices. It can initialize and operate all devices residing on the loop and it communicates all relevant devices and event information, such as alarms and troubles, to the System Central Processing Unit. (CPU). Learn More...Call for price
Out of stock
-
Maple Armor FW337 Notification Output Unit - Support 2 Independent Notification Appliance Circuits - 24Vdc
FW337 is a subassembly for the FW106 FACP (Fire Alarm Control Panel). The NOU supports two independent notification appliance circuits. The circuit topology supports Class A or Class B wiring. The maximum current is 2A per NAC, for a maximum of 4A total per NOU. The address is set by the rotary switch on the board. The valid address range is 1~5. Learn More...Call for price
Out of stock
-
Maple Armor FW347 ROU - Relay Output Unit Supports 5 Dry Contact Relays - 24Vdc
FW347 is a subassembly for the FW106 FACP (Fire Alarm Control Panel). The ROU supports five dry contact relays: Alarm Relay, Supervisory Relay, Trouble Relay, Other Signal Relay, and Programmable Relay. The Relay contacts are in the C Form Style. The address is set by the rotary switch on the board. The valid address is 1. Learn More...Call for price
Out of stock
-
Maple Armor FW357 XNU - External Network Unit - 24Vdc
The FW357 is a subassembly of the FW106 and FW106S FACP (Fire Alarm Control Panel). It provides 1 CAN bus terminals to communicate with panels and annunciators in a Network to form a fire emergency detection and notification network system. The address is set by the rotary switch on the front cover. The valid address is 1. Learn More...Call for price
Out of stock
-
Maple Armor FW391 PTU - Power Supply Transformer Unit - Output 24Vac 12A Max - Input 120-240Vac
The power supply FW391 is a subassembly for the FW106 (FACP Fire Alarm Control Panel). It contains an internal transformer that converts 110-120VAC or 220-240VAC input to 24VAC output, maximum output 12Amps. Learn More...Call for price
Out of stock
-
Maple Armor FW397 - Power Supply and Charger Unit - 24Vdc - Maximum 12Amp
The FW397 power supply and charger is a subassembly for the FW106 FACP (Fire Alarm Control Panel). It provides power supply output to the system (AMI, ALU, NOU, ROU, XNU, Addressable Loop Circuits, Notification Appliance Circuits, Relay output, Network circuits) with regulated 24VDC. Learn More...Call for price
Out of stock
-
Maple Armor FW123 - Remote Annunciator - Powered by Panel Auxiliary Output - Red Color - 24Vdc
FW123 has a 7” color 800×480 resolutions LCD, 6 auxiliary function keys, and 9 LED indicators making it the most intuitive fire-alarm user interface. In total, up to 110 annunciators or 110 panels can be connected to the FW106/FW106S FACP via CAN bus in Class B to form a fire emergency detection and notification network system. Learn More...Call for price
Out of stock
-
Maple Armor FW129 - Remote LED Annunciator - Display Zone Events from Fire Alarm Control Panel - Dark Gray - 24Vdc
The FW129 is provided with 30 zones (2 LEDs + 1 button / zone) for alarm/ audible/trouble events display & control. It also comes with 35 zones (2 LEDs / zone) for alarm/audible/trouble events display. The control part of the annunciator provides information led (power, generic trouble, signal silence, ground fault) & audible on status. There are buttons to operate local buzzer silence, signal silence, lamp test and events reset. Learn More...Call for price
Out of stock
-
Maple Armor FW751 - Non-Addressable Manual Station - 12 to 33Vdc - Red with Window Cover
FW751 or FW751C is normally open initiating device made from durable materials and solid parts for long-lasting performance. In case of fire, an alarm signal is generated by lifting the cover and pushing the button. A reset key (included) with the manual station. Terminals 3 & 4 are normally open dry contacts. Learn More...Call for price
Out of stock
-
Maple Armor FW752 - Non-Addressable Manual Station - 12 to 33Vdc - Red with Window Cover
FW751 or FW752 is normally an open initiating device made from durable materials and solid parts for longlasting performance. In case of fire, an alarm signal is generated by lifting the cover and pushing the button. A reset key (included) with the manual station. Termnals 3 & 4 are normally open dry contact, FW752 NC has normally closed dry contact. Learn More...Call for price
Out of stock
-
Maple Armor FW434 Module Box - Fit up to 16 Modules - 23" W x 13" H x 4" D
The FW434 and FW435 are module boxes allowing the installation of multiple Maple Armor modules into one cabinet. FW434 can fit up to 16 modules and FW435 can fit up to 8 modules. They integrate an external door, two mounting plates, and a backbox. Learn More...Call for price
Out of stock
-
Maple Armor FW435 Module Box - Fit up to 8 Modules - 14" W x 13" H x 4" D
The FW434 and FW435 are module boxes allowing the installation of multiple Maple Armor modules into one cabinet. FW434 can fit up to 16 modules and FW435 can fit up to 8 modules. They integrate an external door, two mounting plates, and a backbox. Learn More...Call for price
Out of stock
-
Maple Armor FW811 - Input Module Monitors a Single Contact - 24Vdc - Compatible EOLR FW421 (10K Ohms)
The FW811 input module monitors a single contact. The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. Learn More...Call for price
Out of stock
-
Maple Armor FW811M - Mini Input Module Monitors a Single Contact - 24Vdc - Compatible EOLR FW421 (10KΩ)
The FW811M Input Module is designed to be inserted into a single gang utility box next to the dry contact device that it is monitoring. A remote red LED indicator connected to the red & black wires is used to show the module’s status. Learn More...Call for price
Out of stock
-
Maple Armor FW812 - Dual Input Module Supports two Class B Input Circuits - 24Vdc
The FW812 dual input module supports two Class B input circuits, each of which can monitor a dry contact device. The input line is monitored for open line faults and ground faults, and the contact must be wired with an end-of-line resistor. Learn More...Call for price
Out of stock