Additional Information
Stock Code | DS-4C |
---|---|
Brand | OUELLET |
UPC | 720825512211 |
Voltage (V) | 240V |
Amperage | 30A |
Operates | Residential Driveway, Sidewalk, Access Ramp,Underground Parking Ramp, Boarding Platforms For Animals. |
UL Listed | cSAus |
Warranty | 10-Year Warranty On The Heating Cable |
Features
Voltage
• 240/208V, 1-phase.
Construction
• Series heating cable set, twin conductor type.
• Heating cable held as a mat at regular 3’’ (76 mm) spacing with flexible strips.
• Fluoropolymer (ECTFE) resistance wire insulation 0.014’’ (0.35 mm) thick.
• Braided copper shielding 17 AWG, serves as ground.
• Polyolefin (EPR) outer sheath insulation 0.08’’ (2 mm) thick.
Watt density
• 50W/sq. ft. (538W/sq. m) at 240V and 347V, 37.5 W/sq. ft. (404W/sq. m) at 208V, 3’’ (76 mm) spacing.
Dimension
• 24’’ (610 mm) and 36’’ (914 mm) wide mats offered in several lengths.
Cold lead
• 50’ (15 m) long.
• 12 AWG or 14 AWG (according to maximum allowable load).
• PVC outer sheath insulation 0.03’’ (0.76 mm) thick.
• 3/8’’ (9.5 mm) outer diameter.
Included materials
• Measurements table label (to be placed in electrical panel).
Installation
• Never cut or shorten the heating cable.
• For outdoor applications only.
• The heating cable must be completely embedded in concrete, asphalt or stone dust under paving.
• Minimum installation temperature -15 °C (5 °F).
• Maximum long-term exposure temperature 105 °C (221 °F).
• Maximum exposure temperature for 10 minutes 220 °C (428 °F).
Warranty
• 10-year warranty on the heating cable.
Application
• Residential driveway, sidewalk, access ramp, underground parking ramp, boarding platforms for animals.