Electrical
-
Leviton GSPA2-Y - Self-Test Automatic Reset Panel Mount GFCI - 20 Amp - 120 VAC - Impact-Resistant Housing - Yellow
20 Amp, 120 VAC, Self-Test Automatic Reset Panel Mount GFCI, Impact-Resistant Housing, Yellow
Learn More...$90.62 -
Leviton D2GF2-KW - 20A - 125 V - Self Test - Tamper-Resistant Smart GFCI Outlet with LED Indicator Light - 20 Amp Feed-Through - Wi-Fi Certified Smart GFCI Receptacle/Outlet - White
20 Amp, Self Test, Tamper-Resistant Smart GFCI Outlet with LED Indicator Light
20A, 125V, 20A Feed-Through, Wi-Fi® Certified Smart GFCI Receptacle/Outlet - White Only
Learn More...$67.24 -
Leviton D2GF1-KW - 15A - 125 V - Self Test - Tamper-Resistant Smart GFCI Outlet with LED Indicator Light - 20 Amp Feed-Through - Wi-Fi Certified Smart GFCI Receptacle/Outlet - White
15 Amp, Self Test, Tamper-Resistant Smart GFCI Outlet with LED Indicator Light
15A, 125V, 20A Feed-Through, Wi-Fi® Certified Smart GFCI Receptacle/Outlet - White Only
Learn More...$66.96 -
Lind Equipment LECI-402403 - High-Powered ELCI - 240 Volts - 40 Amps - 3-Phase - 2' of 10/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,190.00 -
Lind Equipment LECI-301201 - 30 Amp High-Powered GFCI - 120 Volts - Single Phase - 2' of 10/3 SJEOOW Cord - 6mA Trip Level
- Frequency: 60Hz
Learn More...
- Cable Configuration: 2’ Yellow, SJEOOW cable, bare ends
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Automatic (manual reset available upon request)
- Enclosure: NEMA 4X and 6P wet location rated
- Switching Interface: Double insulated and recessed$496.00 -
Lind Equipment LECI-302083 - 30 Amp High-Powered GFCI - 208 Volts - 3-Phase - 2' of 10/4 SJEOOW Cord - 6mA Trip Level
- Frequency: 60Hz
Learn More...
- Cable Configuration: 2’ Yellow, SJEOOW cable, bare ends
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Automatic (manual reset available upon request)
- Enclosure: NEMA 4X and 6P wet location rated
- Switching Interface: Double insulated and recessed$696.00 -
Lind Equipment LECI-302403 - 30 Amp High-Powered GFCI - 240 Volts - 3-Phase - 2' of 10/4 SJEOOW Cord - 6mA Trip Level
- Frequency: 60Hz
Learn More...
- Cable Configuration: 2’ Yellow, SJEOOW cable, bare ends
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Automatic (manual reset available upon request)
- Enclosure: NEMA 4X and 6P wet location rated
- Switching Interface: Double insulated and recessed$770.00 -
Lind Equipment LECI-601201 - High-Powered ELCI - 120 Volts - 60 Amps - Single Phase - 6' of 6/3 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,356.00 -
Lind Equipment LECI-402401 - High-Powered ELCI - 240 Volts - 40 Amps - Single Phase - 6' of 8/3 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$2,910.00 -
Lind Equipment LECI-402083 - High-Powered ELCI - 208 Volts - 40 Amps - 3-Phase - 2' of 10/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,190.00 -
Lind Equipment LECI-404803 - High-Powered ELCI - 480 Volts - 40 Amps - 3-Phase - 6' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,348.00 -
Lind Equipment LECI-602083 - High-Powered ELCI - 208 Volts - 60 Amps - 3-Phase - 6' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,618.00 -
Lind Equipment LECI-602403 - High-Powered ELCI - 240 Volts - 60 Amps - 3-Phase - 6' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,576.00 -
Lind Equipment LECI-604803 - High-Powered ELCI - 480 Volts - 60 Amps - 3-Phase - 6' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,696.00 -
Lind Equipment LECI-606003 - High-Powered ELCI - 600 Volts - 60 Amps - 3-Phase - 2' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$4,042.00 -
Leviton AGRBF-W - SmartlockPro® Dual Function Blank AFCI/GFCI Receptacle - 20 Amp - 125 Volt - Back and Side Wired - 2-Pole - 3-Wire - White
20 Amp Feed-Through, 125 Volt Dual Function Blank AFCI/GFCI Receptacle/Outlet, Monochromatic, back and side wired, wallplate/faceplate sold separately, self-grounding clip included, White
Learn More...$60.26 -
Leviton GFRBF-XE - Self-Test SmartlockPro Slim Blank GFCI Receptacle/Outlet - 20 Amp Feed- Through - 125 Volt - Monochromatic - Back and Side Wired - Black
20 Amp Feed- Through, 125 Volt Receptacle/Outlet, Self-test SmartlockPro Slim Blank GFCI, monochromatic, back and side wired, wallplate/faceplate sold separately,self grounding clip included, Black
Learn More...$42.34 -
Lind Equipment 14880-2402 - 14880 Series GFCI Quad Box Set - 120 Volts - 15 Amps - 2' 12/3 SJTW Cord
GFCI plug and quad box set with circuit breaker built into the box for convenient overload protection. Spring loaded covers protect each pair of receptacles on this impact resistant polymer box. Good for indoor and outdoor use. 12/3 SJTW cord comes in lengths between 2’ and 50’.
Learn More...$158.40 -
Lind Equipment 14880-2406 - 14880 Series GFCI Quad Box Set - 120 Volts - 15 Amps - 6' 12/3 SJTW Cord
GFCI plug and quad box set with circuit breaker built into the box for convenient overload protection. Spring loaded covers protect each pair of receptacles on this impact resistant polymer box. Good for indoor and outdoor use. 12/3 SJTW cord comes in lengths between 2’ and 50’.
Learn More...$184.80 -
Lind Equipment 14880-2425 - 14880 Series GFCI Quad Box Set - 120 Volts - 15 Amps - 25' 12/3 SJTW Cord
GFCI plug and quad box set with circuit breaker built into the box for convenient overload protection. Spring loaded covers protect each pair of receptacles on this impact resistant polymer box. Good for indoor and outdoor use. 12/3 SJTW cord comes in lengths between 2’ and 50’.
Learn More...$230.00