GFCIs and AFCIs
-
Lind Equipment LECI-606003 - High-Powered ELCI - 600 Volts - 60 Amps - 3-Phase - 2' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$4,042.00 -
Lind Equipment LECI-604803 - High-Powered ELCI - 480 Volts - 60 Amps - 3-Phase - 6' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,696.00 -
Lind Equipment LECI-302403 - 30 Amp High-Powered GFCI - 240 Volts - 3-Phase - 2' of 10/4 SJEOOW Cord - 6mA Trip Level
- Frequency: 60Hz
Learn More...
- Cable Configuration: 2’ Yellow, SJEOOW cable, bare ends
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Automatic (manual reset available upon request)
- Enclosure: NEMA 4X and 6P wet location rated
- Switching Interface: Double insulated and recessed$770.00 -
Lind Equipment LECI-602403 - High-Powered ELCI - 240 Volts - 60 Amps - 3-Phase - 6' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,576.00 -
Lind Equipment LECI-404803 - High-Powered ELCI - 480 Volts - 40 Amps - 3-Phase - 6' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,348.00 -
Lind Equipment LECI-602083 - High-Powered ELCI - 208 Volts - 60 Amps - 3-Phase - 6' of 6/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,618.00 -
Lind Equipment LECI-402403 - High-Powered ELCI - 240 Volts - 40 Amps - 3-Phase - 2' of 10/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,190.00 -
Lind Equipment LECI-402083 - High-Powered ELCI - 208 Volts - 40 Amps - 3-Phase - 2' of 10/4 SOOW Cord - 6/10/30mA Trip Level
- Frequency: 60Hz
Learn More...
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Field selectable – automatic or manual reset
- Enclosure: NEMA 4X wet location rated
- Switching Interface: Double insulated and recessed$3,190.00 -
Lind Equipment LECI-302083 - 30 Amp High-Powered GFCI - 208 Volts - 3-Phase - 2' of 10/4 SJEOOW Cord - 6mA Trip Level
- Frequency: 60Hz
Learn More...
- Cable Configuration: 2’ Yellow, SJEOOW cable, bare ends
- Response Time: 25mS max at 500 ohm fault
- Operating Temperature: -35ºC to 66ºC
- Reset Type: Automatic (manual reset available upon request)
- Enclosure: NEMA 4X and 6P wet location rated
- Switching Interface: Double insulated and recessed$696.00