Skip to Main Content »

Search Site
Your shopping cart is empty

All Prices are in Canadian Dollars

Lovato PMA20240 - CURRENT MONITORING RELAY FOR SINGLE-PHASE SYSTEM - AC/DC MAXIMUM CURRENT CONTROL - 5A OR 16A

Be the first to review this product

Lovato PMA20240 - CURRENT MONITORING RELAY FOR SINGLE-PHASE SYSTEM - AC/DC MAXIMUM CURRENT CONTROL - 5A OR 16A

 

Availability: In stock

$246.11

Lovato PMA20240 - CURRENT MONITORING RELAY FOR SINGLE-PHASE SYSTEM - AC/DC MAXIMUM CURRENT CONTROL - 5A OR 16A

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code PMA20240
Brand Lovato
UPC 8013975172810
Voltage (V) 24...240VAC/DC
Amperage 5/16A
Amp Rating 5/16A
Wattage (w)
Phase Single Phase
UL Listed cULus,EAC
Notes HS Code: 85364900
Cross Refefence Conformity:
IEC/EN 60255-5
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CSA C22.2 n° 14

General characteristics

– Current monitoring relay for AC/DC maximum current control, AC/DC multivoltage auxiliary power supply
– Direct connection up to 16A max or by current transformer (CT)
– Excellent tripping accuracy
– TRMS current measurements (True Root Mean Square)
– Resetting and inhibition input
– 1 relay output with 1 changeover contact (SPDT)
– Modular DIN 43880 housing, 2 module
– IEC degree of protection: IP40 on front (only when placed in IP40 enclosure or control board); IP20 at terminals.

ADJUSTMENTS

"Imax" Maximum current tripping threshold 5...100% Ie
"Hysteresis" Maximum hysteresis thresold 1...50%
"Trip delay" Tripping time 0.1...30s
"Inhibition time" Inhibition delay for external input or at power up 1...60s
“Aut. reset delay” Automatic resetting time 0.1...30s
“Mode” • Rated current 5A or 16A
• Relay output normally energised or de-energised
• Tripping memory (Latch) On or Off.

Certifications and compliance

Certifications obtained: EAC; UL Listed, for USA and Canada (cULus - File E93601), as Auxiliary Devices - Modular ampere monitoring relays.
Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14.

 


Lovato PMV20A600 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 380...600VAC 50/60HZ

$271.30

$159.90


Lovato PMV30A600 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - MINIMUM AC VOLTAGE - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 600VAC 50/60HZ
$332.60

Lovato PMA30240 - CURRENT MONITORING RELAY FOR SINGLE-PHASE SYSTEM - AC/DC MINIMUM OR MAXIMUM CURRENT CONTROL - 5A OR 16A
$321.61

Lovato PMV20A240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 100…240VAC 50/60HZ

$271.30

$159.90


Lovato PMV70NA440 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS AND ASYMMETRY - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 380…575VAC 50/60HZ
$654.21

Lovato PMA50A415 - PUMP PROTECTION RELAY FOR SINGLE AND THREE-PHASE SYSTEMS - MAXIMUM AC CURRENT AND MINIMUM COSΦ - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 5A OR 16A
$496.03

Lovato PMV50NA240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 208…240VAC 50/60HZ
$519.56

Lovato PMA40240 - CURRENT MONITORING RELAY FOR SINGLE-PHASE SYSTEM - AC/DC MINIMUM AND MAXIMUM CURRENT CONTROL - 0.02 - 0.05 - 0.25 - 1 - 5 - 16A
$480.56

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.