Skip to Main Content »

Search Site
Your shopping cart is empty

All Prices are in Canadian Dollars

Lovato PMV30A575 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - MINIMUM AC VOLTAGE - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 380...575VAC 50/60HZ

Be the first to review this product

Lovato PMV30A575 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - MINIMUM AC VOLTAGE - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 380...575VAC 50/60HZ

 

Availability: In stock

$358.25

Lovato PMV30A575 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - MINIMUM AC VOLTAGE - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 380...575VAC 50/60HZ

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code PMV30A575
Brand Lovato
UPC 8013975142158
Voltage (V) 380...575VAC
Wattage (w)
Phase Three Phase
UL Listed cULus , EAC
Notes HS Code: 85364900
Cross Refefence Conformity:
IEC/EN 60255-5
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CSA C22.2 n° 14

General characteristics

– Voltage monitoring relay, self powered, for minimum voltage, phase loss and incorrect phase sequence
– Configurable rated voltage (Ue):
• PMV30 A240: 208-220-230-240VAC
• PMV30 A575: 380-400-415-440-460-480-525-575VAC
– Excellent tripping accuracy
– TRMS measurements (True Root Mean Square)
– Control of phase-to-phase voltages
– Phase loss detection if one of the voltages is <70% rated value
– Phase loss tripping time: 60ms
– 1 relay output with 1 changeover contact (SPDT)
– Modular DIN 43880 housing, 2 module
– IEC degree of protection: IP40 on front (only when placed in IP40 enclosure or control board); IP20 at terminals.

ADJUSTMENTS
“V min” Minimum voltage tripping threshold 80...95% Ue
“Delay” Tripping time 0.1...20s
“Reset delay” Resetting time 0.1...20s.

Certifications and compliance

Certifications obtained: EAC; UL Listed, for USA and Canada (cULus - File E93601), as Auxiliary Devices.
Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14.


Lovato PMV60A240, Voltage Monitoring Realy for Three-phase System, Without Neutral, Minimum AC Voltage and Asymmetry. Phase Loss and Incorrect Phase Sequence, 208...240VAC 50/60Hz
$581.32

Lovato PMA60A415 - PHASE SHIFT MONITORING RELAY FOR SINGLE AND THREE-PHASE SYSTEMS - MINIMUM AND MAXIMUM COSΦ - 16A
$426.59

Lovato PMV40A240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - ASYMMETRY - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 208...240VAC 50/60HZ
$387.52

Lovato PMV60A600, Voltage Monitoring Realy for Three-phase System, Without Neutral, Minimum AC Voltage and Asymmetry. Phase Loss and Incorrect Phase Sequence, 600VAC 50/60Hz
$581.32

Lovato PMV80NA440 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - MINIMUM AND MAXIMUM FREQUENCY - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 380…575VAC 50/60HZ
$784.30

Lovato PMV70NA600 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS AND ASYMMETRY - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 480...600VAC 50/60HZ
$654.21

Carlo Gavazzi CTG035 - Core Balance Transformer - Internal Diameter 35mm - Current Transfomrer Ratio 1000/1 - Max. System Voltage 720Vac
$87.36

Lovato PMV10A440 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 208…480VAC 50/60HZ
$242.24

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.