Skip to Main Content »

Search Site
Your shopping cart is empty

All Prices are in Canadian Dollars

Lovato DCRM2 - REATIVE CURRENT CONTROLLER RELAY - DCRM SERIES - SINGLE AND THREE-PHASE LOW-VOLTAGE SYSTEM - 2 STEPS

Be the first to review this product

Lovato DCRM2 - REATIVE CURRENT CONTROLLER RELAY - DCRM SERIES - SINGLE AND THREE-PHASE LOW-VOLTAGE SYSTEM - 2 STEPS

 

Availability: In stock

$521.78

Lovato DCRM2 - REATIVE CURRENT CONTROLLER RELAY - DCRM SERIES - SINGLE AND THREE-PHASE LOW-VOLTAGE SYSTEM - 2 STEPS

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code DCRM2
Brand Lovato
UPC 8013975189160
UL Listed EAC , cULus
Notes HS Code: 85389091

General characteristics

The DCRM allows the reactive current of a system to be controlled.
It can correct to the best cos value possible, reducing the request for reactive current from the mains.
It can control the connection of two capacitor banks.
Each one can be individually enabled and its power can be set through a dedicated trimmer.
It is also possible to adjust the time for connection and disconnection of the capacitors, thereby modifying the reaction speed of the system.
The controller can be used both in three- and singlephase wiring.

Operational characteristics

– Auxiliary supply voltage:
• 380...415VAC standard
• 220...240VAC and 440...480VAC on request
– Rated frequency: 50/60Hz
– 80...528VAC voltage measurement input
– Current measurement input:
• By CT /5A
• Measuring range: 0.1...6A
• Measurement type: true root mean square (TRMS)
• Automatic identification of CT connection polarity (straight / inverted)
– Relay outputs:
• 2 relays (steps), each with 1 changeover contact
• Rated current: 8A 250VAC (AC1)
• Individual enablement of control of the two relays
– Modular DIN 43880 housing (3 modules)
– IEC degree of protection: IP40 on front (if placed in IP40 housing and/or electrical panel), IP20 terminals.

ADJUSTMENTS
“C/K Step 1”                 C/K ratio step 1 (0.15...2)
“C/K Step 2”                 C/K ratio step 2 (0.15...2)
“Connection delay”       Step connection delay 1...60s
“Disconnection delay”   Step disconnection delay 0.1...60s
“System configuration”  Single- or three-phase wiring selection.

INDICATIONS
– 1 green LED for power on and inhibition time
– 2 red LEDs for relay connection.

Certifications and compliance

Certifications obained: EAC; UL Listed, for USA and Canada (File E93601), as Auxliary Devices-Modular ampere monitoring relays (with 415VAC maximum only).
Compliant with standards: IEC/EN 60255-5, IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL508, CSA C22.2 n°14.