Additional Information
Stock Code | DMG110 |
---|---|
Brand | Lovato |
UPC | 8013975214879 |
UL Listed | EAC , cULus , RCM , GOST |
Notes | HS Code: 90303100 |
Cross Refefence | Conformity: IEC/EN 61010-1 IEC/EN 61010-2-030 IEC/EN 61000-6-2 IEC/EN 61000-6-3 UL61010-1 CSA 22.2 n°61010-1 |
General characteristics
DMG... digital multimeters are available with a modular housing, 4 module size, and are equipped with a graphic backlight LCD (except DMG 100/101/110 with icon display) capable of providing extremely clear, intuitive and flexible viewing of all electrical parameters of an installation.
For DMG 110 and DMG 210 versions, there is a built-in isolated RS485 interface, while DMG 101 features 2 programmable digital inputs and 2 outputs.
Main measurements:
– Voltage: phase, line and system values
– Current: phase values (neutral current calculated)
– Power: apparent, active and reactive phase and total values
– P.F.: Power Factor per phase and total
– Frequency of measured voltage value
– HIGH-LOW-AVERAGE value functions of all measurements
– Maximum demand of power and current values
– Asymmetric voltage and current
– Total harmonic distortion (THD) of voltage and current values
– Energy meters for active, reactive and apparent values
– Hour counter (total and partial, 1 on DMG 200/210, 4 programmable on DMG 100/101/110)
– Phase energy (DMG 100/110)
– Harmonic analysis up to the 15th order (DMG 100/110).
Operational characteristics
– Auxiliary supply voltage range: 85...264VAC / 93,5...300VDC
– Maximum rated measurement voltage
• 600VAC (DMG 100/101/110)
• 690VAC (DMG 200/210)
– Voltage measurement range:
• 50...720VAC phase-to-phase (DMG 100/101/110)
• 20...830VAC phase-to-phase (DMG 200/210)
– Usage in medium and high-voltage systems with voltage transformers
– Rated input current: With external CT /5A (also 1A for DMG 100/101/110)
– Current measurement range with CT up to 10,000A
– Frequency measurement range: 45-66Hz
– True RMS measurements for voltage and current values
– Accuracy:
• Voltage: ±0,5% (50...720VAC for DMG 1...) (50...830VAC) for DMG 2...
• Current: ±0,5% (0,1...1,1In)
• Power: ±1% f.s.
• Frequency: ±0,05%
• Active energy: Class 1 (IEC/EN 62053-21)
• Reactive energy: Class 2 (IEC/EN 62053-23)
– Non-volatile memory for data storage
– Communication protocol Modbus-RTU and ASCII (only for DMG 210 and DMG 110)
– Programming and remote control by software (only for DMG 210 and DMG 110; compatible with Synergy and Xpress software)
– Modular housing, 4 module
– Degree of protection: IP40 on front; IP20 at terminals.
CURRENT TRANSFORMERS OF DMG… KITS
– Operating frequency: 50…60Hz
– Secondary output current: 5A
– Overload withstand: 120% Ipn
– Rated insulation voltage Ui: 720V
– Rated short time thermal current Ith: 40…60Ipn for 1 second
– Rated dynamic current Idyn: 2.5Ith for 1 second
– Insulation (dry type): class E
– Faston terminals
– Degree of protection: IP30.
Synergy supervision and energy management software See Section 27.
Xpress configuration and remote control software See Section 27.
Certifications and compliance
Certifications obtained: EAC for all; UL Listed for USA and Canada (cULus - File E93601), as Auxiliary Devices - Multimeter for DMG 1.../DMG 2... types.
Compliant with standards: IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/EN 61000-6-4; UL61010-1, CSA C22.2 n° 61010-1 for DMG 100/110 (DMG 101 pending); UL508, CSA C22.2 n° 14 for DMG 200/210; IEC/EN 60044-1 for transformers of starter kits.