Lovato DMG900 - FLUSH-MOUNT LCD TOUCH-SCREEN POWER ANALYZER - EXPANDABLE - GRAPHIC 128X112 PIXEL TOUCH-SCREEN LCD - HARMONIC ANALYSIS - 4 CURRENT CHANNELS, (NEUTRAL MEAS.) AUXILIARY SUPPLY 100-440VAC/110-250VDC - MULTILANGUAGE - ITALIAN - ENGLISH - FRENCH

Be the first to review this product

Lovato DMG900 - FLUSH-MOUNT LCD TOUCH-SCREEN POWER ANALYZER - EXPANDABLE - GRAPHIC 128X112 PIXEL TOUCH-SCREEN LCD - HARMONIC ANALYSIS - 4 CURRENT CHANNELS, (NEUTRAL MEAS.) AUXILIARY SUPPLY 100-440VAC/110-250VDC - MULTILANGUAGE - ITALIAN - ENGLISH - FRENCH - SPANISH AND PORTUGUESE

 

Availability: In stock

$3,443.05

Lovato DMG900 - FLUSH-MOUNT LCD TOUCH-SCREEN POWER ANALYZER - EXPANDABLE - GRAPHIC 128X112 PIXEL TOUCH-SCREEN LCD - HARMONIC ANALYSIS - 4 CURRENT CHANNELS, (NEUTRAL MEAS.) AUXILIARY SUPPLY 100-440VAC/110-250VDC - MULTILANGUAGE - ITALIAN - ENGLISH - FRENCH

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code DMG900
Brand Lovato
UPC 8013975180563
UL Listed EAC , cULus , RCM , GOST
Notes HS Code: 90303100
Cross Refefence Conformity:
IEC/EN 61010-1
IEC/EN 61000-6-2
IEC/EN 61000-6-4
UL508
CSA C22.2 n°14

General characteristics

DMG 900... expandable digital power analyzers are available with a flush-mount housing, 96x96mm/3.78”x3.78”.
The wide graphic touch screen display provides extremely simple interacting between the device and the user.
The high performance of the power analyzers gives very accurate measurements and can control energy distribution networks, to detect and prevent energy problems which could compromise quality and supply.
The main features include an extensive power supply voltage range, high measurement accuracy, expandability up to 4 plug in expansion modules.
There also is available the DMG 900T measurement transducer which can be used with the DMG 900RD remote display. The DMG 900T, without display, is arranged for mounting inside the panel board, on 35mm DIN rail, and is an ideal solution for installations where the measurements of various multimeters must be remotely viewed.
The DMG 900RD remote display connected to the DMG 900T transducer can display the measurements on the panel front while power connections remain inside the panel.

Main measurements and functions include:
– Voltage: phase, phase-neutral and ground neutral-earth
– Supply voltage value (only DMG... D048)
– Current: phase values
– Neutral current calculated and true values
– Power: apparent, active and reactive phase and total values
– P.F.: Power Factor per phase and total
– Cos per phase and total
– Frequency of measured voltage value
– Voltage and current asymmetry
– Total harmonic distortion (THD) of voltage and current
– Harmonic analysis of voltage and current up to the 63° order
– HIGH-LOW-AVERAGE value functions for all measurements
– Maximum demand of power and current values
– Energy meters for active, reactive, apparent partial and total values with programmable tariff functions
– Hour counter for programmable total and partial hours
– Pulse counter for general use: consumption pulse counting for water, gas, etc., with expansion module only
– Energy quality analysis to EN 50160 Class B (with expansion module).

Operational characteristics

– Auxiliary supply voltage range: 90...484VAC / 93,5...300VDC for DMG 900 and DMG 900T; 9...70VDC for DMG 900 D048 and DMG 900T D048
– Voltage measurement range: 20...830VAC phase-to-phase 10...480VAC phase-neutral
– Usage in medium and high-voltage systems with voltage transformers
– rated input current: 5A or 1A via CT
– Current measurement range: 0,05...10A o 0,01...1.2A
– Current measurements via CT up to 10,000A
– Frequency measurement range: 45...66Hz / 360...440Hz
– True RMS measurements for voltage and current values
Accuracy:
• Voltage: ±0,2% (50...830VAC)
• Current: ±0,2% (0.1...1.1In)
• Power: ±0,5% f.s.
• Power factor: ±0,5%
• Frequency: ±0.05%
• Active energy: Class 0.5s (IEC/EN 62053-22)
• Reactive energy: Class 2 (IEC/EN 62053-23)
– Non-volatile memory for data and event (last 100) storage
– Communication protocol Modbus-RTU, ASCII and TCP with communication expansion modules only
– Programming and remote control by software with communication expansion modules only
– Housing: 96x96mm/3.78”x3.78” flush mount (for DMG 900... and DMG 900RD) and 35mm DIN rail (for DMG 900T...)
– Degree of protection: IP65 on front for DMG 900 - DMG 900RD; IP20 at terminals for DMG 900 - DMG 900T.

Synergy supervision and energy management software See Section 27.

Xpress configuration and remote control software See Section 27.

EXP series expansion modules See page 28-2.

Certifications and compliance

Certifications obtained: EAC for all except DMG M3...; UL Listed, for USA and Canada (cULus - File E93601), as Auxiliary Devices-Multimeters for all except DMG M3...
Compliant with standards: IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n°14.