Maple Armor FW811 - Input Module Monitors a Single Contact - 24Vdc - Compatible EOLR FW421 (10K Ohms)

Be the first to review this product

The FW811 input module monitors a single contact. The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel.
 

Availability: In stock

Call for price

Maple Armor FW811 - Input Module Monitors a Single Contact - 24Vdc - Compatible EOLR FW421 (10K Ohms)

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code FW811
Brand Maple Armor
Family Input Module
Voltage (V) 15 to 28 VDC
Amperage Standby Current 0.17mA, Alarm Current 0.79mA
Length (in) 120mm
Width (in) 120mm
Height (in) 45mm
Mounting FW800 / FW801 Base
Operates Max. Line Impedance 25 Ohms, Max. Impedance for Grounding 6.6 K Ohms, Compatible EOLR FW421 (10K Ohms)
Wire Gauge 18-12 AWG
Start Temp. (Min) 32°F / 0°C
Start Temp. (Max) 120°F / 49°C
UL Listed UL, cUL listed
Notes • Alarm Causing: An alarm causing input will produce an ALARM event. The device red LED will indicate the alarm condition by turning on steady. A return to the normal condition will be ignored and the device LED indicator will remain latched in the red alarm condition until a reset command has been received.

• Supervisory/Trouble/Monitor Causing: By changing the FW811 input module functions from its attribute interface on FACP, it can be configured to be a supervisory, trouble, or monitor signal, which will produce aSUPERVISORY, TROUBLE, or MONITOR event. The device red LED will indicate the event condition by turning on steady. The supervisory and monitor are latched/non-latched selectable. A return to the normal condition will cause the event to disappear and the device LED indicator will return to the normal condition if the supervisory/monitor is nonlatched. A return to the normal condition will not cause the event to disappear and the device LED indicator will remain in event condition if the supervisory/monitor is latched. The trouble is non-latched.

The FW811 is a UL/ULC listed device according to UL864 and ULC-S527 for Fire Protective Signaling Systems for indoor use and FM. The type of input contact is configurable.