Maple Armor FW811M - Mini Input Module Monitors a Single Contact - 24Vdc - Compatible EOLR FW421 (10KΩ)

Be the first to review this product

The FW811M Input Module is designed to be inserted into a single gang utility box next to the dry contact device that it is monitoring. A remote red LED indicator connected to the red & black wires is used to show the module’s status.
 

Availability: In stock

Call for price

Maple Armor FW811M - Mini Input Module Monitors a Single Contact - 24Vdc - Compatible EOLR FW421 (10KΩ)

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code FW811M
Brand Maple Armor
Family Mini Input module
Voltage (V) 15 to 28 VDC
Amperage Standby Current 0.17mA, Alarm Current 0.80mA
Operates Max. Line Impedance 25 Ω, Max. Impedance for Grounding 6.6 KΩ, Compatible EOLR FW421 (10KΩ)
Start Temp. (Min) 32°F / 0°C
Start Temp. (Max) 120°F / 49°C
UL Listed UL, cUL listed
Notes • Alarm Causing: An alarm causing input will produce an ALARM event. The device red LED will indicate the alarm condition by turning on steady. A return to the normal condition will be ignored and the device LED indicator will remain latched in the red alarm condition until a reset command has been received.

• Supervisory/Trouble/Monitor Causing: By changing the FW811 input module functions from its attribute interface on FACP, it can be configured to be a supervisory, trouble, or monitor signal, which will produce aSUPERVISORY, TROUBLE, or MONITOR event. The device red LED will indicate the event condition by turning on steady. The supervisory and monitor are latched/non-latched selectable. A return to the normal condition will cause the event to disappear and the device LED indicator will return to the normal condition if the supervisory/monitor is nonlatched. A return to the normal condition will not cause the event to disappear and the device LED indicator will remain in event condition if the supervisory/monitor is latched. The trouble is non-latched.

The FW811M input module monitors a single contact. The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. The FW811M is a UL/ULC listed device according to UL864 and ULC-S527 for Fire Protective Signaling Systems for indoor use. The type of input event is configurable.