Fan Blower Controls
-
ALLTEMP 24-ICM253 - Fan Blower Controls
Voltage:18-30VAC
1 Amp Max
40 mA Min.
10 Amp Inrush
Adjustable time delay 12-390 seconds
Dimensions: 2"×3"
Learn More...$66.64 -
ALLTEMP 24-ICM284 - Fan Blower Controls - Microprocessor based
Line Voltage: 208 VAC @ 60 Hz
Ignitor: 5A resistive @ 208 VAC
Cool Blower: 30A, 2HP @ 240 VAC
Heat Blower: 10A, .5HP @ 250 VAC
Inducer Motor: 4A, 120 VAC
Gas Valve: 4A @ 24 VAC
Compressor: 5A resistive @ 24 VAC
Learn More...$684.32 -
ALLTEMP 24-ICM286 - Fan Blower Controls
- Voltage Range: Line (98-132 VAC) @ 60Hz
- Cool Blower: 30A, 2 HP, 240 VAC
- Heat: 20A, 240 VAC
- Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
- Ignitor: 10A FLA @ 120 VAC
- Humidifier: 5 amps @ 120 VAC
- Electric Air Cleaner: 5 amps @ 120 VAC
- Trial for Ignition: 7 seconds
- Pre-purge Time: 15 seconds
- Ignitor Warm Up Time: 7 seconds
- Post-Purge Time: 15 seconds
- Total Trials for Ignition: 3 (auto rest after 1 hour)
- Heat Blower On: 30 seconds
- Heat Blower Off: Selectable 90/120/150/180 seconds
- Fan (Heat) On/Off Delay: 1 second
- Cool On: 5 seconds
- Cool Off: 45 seconds
$133.97 -
ALLTEMP 24-ICM287 - Fan Blower Controls
Line Voltage: 120 VAC @ 60 Hz
Control Voltage: 24 VAC @ 60Hz
Heat Blower: 10A @ 120 VAC
Cool Blower: 30A @ 120 VAC
Inducer Motor: 30A, 120 VAC
Learn More...$221.84 -
ALLTEMP 24-ICM288 - Fan Blower Controls
Voltage Range: Line 98-132 VAC @ 60HZ
Ignitor: 5A, 120 VAC
Cool Blower: 10A, 2HP, 240 VAC
Heat: 5A, 1/2 HP, 250 VAC
Inducer Blower: 4A, 120 VAC
Gas Valve: 1A, 24 VAC
Humidifier Motor: 0.5A, 24 VAC
Electronic Air Cleaner: 1A, 120 VAC
Learn More...$262.59 -
ALLTEMP 24-ICM289 - Fan Blower Controls
ICM Controls ICM289 Furnace Control Replacement for Lennox Control Boards, Replaces All BCC1, BCC2 and BCC3 Circuit Boards
Voltage Range: Line (98 to 132 VAC) @ 60 Hz
Cool Blower: 20A @ 120 VAC
Heat Blower: 20A @ 120 VAC
Inducer Motor: 5A @ 120 VAC
Cool Blower On Delay: 1 second
Cool Blower Off Delay: 1 second
Heat Blower On Delay: 45 seconds
Heat Blower Off Delay: 90, 150, 210, 270 seconds
Learn More...$417.60 -
ALLTEMP 24-ICM291 - Fan Blower Controls
Control Voltage: 24 VAC (18-30 VAC), 60Hz
Line Voltage: 208/230 VAC, 60Hz
Power Consumption: 03A plus gas valve current @ 24 VAC
Operating Temperature: -40°C(-40°F) to 75°C(176°F)
Timing:
- Pre-purge: 45 seconds
- Trial for Ignition: 5+2 seconds
- Retry Period: every 20 seconds for 15 minutes
- Lockout: manual reset
- Post-purge: 45 seconds
Inputs:
- Power: RT and C
- Thermostat Interface: R, W and G
- Safety Switches: RS, LS and CS
- Combustion Motor Hall Effect Sensor
- Flame Sensing
Outputs:
- Spark
- Gas Valve: GV
- Combustion Motor: BM
- Indoor Fan Motor: IFO
LED Indicators:
- Red LED: Steady ON - Normal operation Flashing - Fault codes
$343.04 -
ALLTEMP 24-ICM292 - Fan Blower Controls
Control Voltage: 24 VAC (18-30 VAC), 60Hz
Line Voltage: 115/23 VAC, 60Hz
Power Consumption: 03A plus gas valve curreny @ 24 VAC
Operating Temperature: -40°C(-40°F) to 75°C(176°F)
Timing:
- Pre-purge: 20 seconds
- Trial for Ignition: 6.5 seconds
- Number of Trials: 4 (2+2, 3 minutes apart)
- Lockout: 1 Hour
- Post-purge: dip switch selectable 90, 120, 160, 180 seconds apart
Inputs:
- Power: SEC and COM
- Thermostat Interface: R, W, Y and G
- Safety Switches: Limit and Vent
- Combustion Motor Hall Effect Sensor
- Flame Sensing
Outputs:
- Spark
- Gas Valve: GV
- Induced Draft Motor
- Multi speed indoor blower motor
- Humidifier
LED Indicators:
- PWR(green): Steady ON - power to the board
- OK(green): Steady ON - no fault
- Flashing - fault code
- Flame(yellow): Steady On - flame sensed, flashing two times -flame out of sequence
$256.98 -
ALLTEMP 24-ICM2801 - Fan Blower Controls
ALLTEMP 24-ICM2801 - Fan Blower Controls Learn More...$478.66 -
ALLTEMP 24-ICM2804 - Fan Blower Controls - Low cost form, fit and functional replacement for Carrier: CES0110074-01
Fan Blower Controls - Low cost form, fit and functional replacement for Carrier: CES0110074-01 Learn More...$390.36 -
ALLTEMP 24-ICM2805A - Fan Blower Controls - Low cost form, fit and functional OEM replacement control board for Nordyne: 903106-Kit
Line Voltage Range: 120/240 VAC @ 60 Hz; Ignitor: 5A, 120 VAC; Cool Blower: 10A, 2HP, 240 VAC; Heat: 5A, 1/2 HP, 250 VAC; Inducer Blower: 4A, 120 VAC; Gas Valve: 1A, 24 VAC; Humidifier Motor: 0.5A, 24 VAC; Electronic Air Cleaner: 1A, 120 VAC
Learn More...$370.27 -
ALLTEMP 24-ICM2807 - Fan Blower Controls - Operating: -40°F to 176°F
Fan Blower Controls - Operating: -40°F to 176°F
Learn More...$835.20 -
ALLTEMP 24-ICM282A - Fan Blower Controls - direct replacement for Carrier HK42FZ004/007/008/009/011/013/016
Voltage Range: Line (98 to 132 VAC) @ 60Hz
Cool Blower: 10A, 2 HP, 240 VAC
Heat: 5A, 1/2 HP, 240 VAC
Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
Gas Valve: 1.5A @ 30 VAC
Heat Blower On: 60 seconds
Heat Blower Off: 90, 120, 150, and 180 sec
Fan (Heat) On/Off: 1-second
Cool On: 2 seconds
Cool Off: 90 seconds with jumper JW2 uncut; 5 seconds with jumper JW2 cut
Learn More...$672.80 -
ALLTEMP 24-ICM281 - Fan Blower Controls - direct replacement board for Carrier CESO11005700/01/02
Voltage Range: Line (98 to 132 VAC) @ 60Hz
Cool Blower: 10A, 2 HP, 240 VAC
Heat: 5A, 1/2 HP, 240 VAC
Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
Gas Valve: 1.5A @ 30 VAC
Heat Blower on Delay: 40 seconds
Heat Blower Off Delays: 90, 135, 180, and 225 seconds
Fan (Low) On/Off: 1-second
Cool Blower on Delay: 5 seconds
Cool Blower Off Delay: 90 seconds
Learn More...$417.60 -
ALLTEMP 24-ICM254 - Fan Blower Controls
Voltage:18-30VAC; 1 Amp Max; 40 mA Min. ; 10 Amp Inrush; Time Delays Adjustable; On - 1-180 seconds; Off - 12-390 seconds; Dimensions: 2"×3"
Learn More...$86.54
-
ALLTEMP 24-ICM255 - Fan Blower Controls
Voltage:18-30VAC
N.O.: 20 Amps @ 240VAC
N.C.: 20 amps @ 240VAC
Time Delays Fixed
On - 1 second
Off - 60 seconds
Dimensions: 2.5"×2.5"
Learn More...$64.03 -
ALLTEMP 24-ICM270 - Fan Blower Controls
Voltage Range: 18-30 VAC
Contact Ratings: Heat/cool speed
- N.O.: 20 amps @ 240 VAC
- N.C.: 10 amps @ 240 VAC
Time Delays:
- Blower ON delay: 30 Seconds
- Blower OFF delay: 90,120,150,180 seconds
$158.50 -
ALLTEMP 24-ICM271 - Fan Blower Controls
Voltage Range: 18-30 VAC
Contact Ratings:
- N.O.: 20 amps
- N.C.: 10 amps
Time Delays:
- Heat ON delay: 75 Seconds
- Heat OFF delay: 105 seconds
- Cool OFF delay: 90 seconds
$185.60 -
ALLTEMP 24-ICM273 - Fan Blower Controls
Voltage Range: 18-30 VAC
Output: 2 amps @ 240 VAC
Time Delays:- Blower OFF delay: 60 seconds
$52.43 -
ALLTEMP 24-ICM274 - Fan Blower Controls
Voltage Range: 18-30 VAC
Learn More...
Contact Ratings:
Y out: 1.5 amps
Fan: 2 amps
Elec. Heat Relay: 30 amps @ 240 VAC
Time Delays: Blower OFF delay: 60-240 seconds$153.22