Skip to Main Content »

Search Site
Your shopping cart is empty

All Prices are in Canadian Dollars

Lovato PMV50NA240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 208…240VAC 50/60HZ

Be the first to review this product

Lovato PMV50NA240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 208…240VAC 50/60HZ

 

Availability: Pre-order in 2-3 weeks

$519.56

Lovato PMV50NA240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 208…240VAC 50/60HZ

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code PMV50NA240
Brand Lovato
UPC 8013975179789
Voltage (V) 208...240VAC
Wattage (w)
Phase Three Phase
UL Listed EAC
Notes HS Code: 85364900
Cross Refefence Conformity:
IEC/EN 60255-5
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
CSA C22.2 n° 14

General characteristics

– Voltage monitoring relay, self powered, for minimum and maximum voltage, phase loss, neutral loss and incorrect phase sequence
– 4 configurable rated voltage (Ue):
• PMV50N A240: 208-220-230-240VAC (phase-phase) 120-127-132-138VAC (phase-neutral)
• PMV50N A440: 380-400-415-440VAC (phase-phase) 220-230-240-254VAC (phase-neutral)
• PMV50N A600: 480-525-575-600VAC (phase-phase) 277-303-332-347VAC (phase-neutral)
– Excellent tripping accuracy
– TRMS measurements (True Root Mean Square)
– Phase loss detection when one of the voltages is <70% rated voltage
– Phase or neutral loss tripping time: 60ms
– 2 relay outputs, each with 1 changeover contact (SPDT)
– Modular DIN 43880 housing, 3 module
– IEC degree of protection: IP40 on front (only when placed in IP40 enclosure or control board); IP20 at terminals.

ADJUSTMENTS

“V max” Maximum voltage tripping threshold 105...115% Ue
“V min” Minimum voltage tripping threshold 80...95% Ue
“Delay” for each Tripping time 0.1...20s
“Reset Delay” Resetting time 0.1...20s.

Certifications and compliance

Certifications obtained: EAC.
Compliant with standards: IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14.

Operational diagram

See page 18-19.


Carlo Gavazzi CTG050 - Core Balance Transformer - Internal Diameter 50mm - Current Transfomrer Ratio 1000/1 - Max. System Voltage 720Vac
$99.00

Lovato PMV30A575 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITHOUT NEUTRAL - MINIMUM AC VOLTAGE - PHASE LOSS AND INCORRECT PHASE SEQUENCE - 380...575VAC 50/60HZ
$358.25

Lovato PMV70NA440 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS AND ASYMMETRY - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 380…575VAC 50/60HZ
$654.21

Carlo Gavazzi DEB71DM24A30 - Earth Leakage Monitoring Relay - Adjustable Trip Level 300mA to 30A - 2 Changeover Replay Output - Power Supply 24-240Vac
$289.99

Lovato PMF20A240 - FREQUENCY MONITORING RELAY FOR SINGLE AND THREE-PHASE SYSTEMS - MINIMUM AND MAXIMUM FREQUENCY - 220…240VAC 50/60HZ
$726.61

Lovato PMV70NA240 - VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM - WITH OR WITHOUT NEUTRAL - MINIMUM AND MAXIMUM AC VOLTAGE - PHASE LOSS AND ASYMMETRY - NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE - 208…240VAC 50/60HZ
$654.21

Carlo Gavazzi CTG210 - Core Balance Transformer - Internal Diameter 210mm - Current Transfomrer Ratio 1000/1 - Max. System Voltage 720Vac
$673.20

Carlo Gavazzi CTG120 - Core Balance Transformer - Internal Diameter 120mm - Current Transfomrer Ratio 1000/1 - Max. System Voltage 720Vac
$192.96

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.