Additional Information
Stock Code | RGK900MC |
---|---|
Brand | Lovato |
UPC | 8013975205235 |
Voltage (V) | 12/24VDC |
UL Listed | EAC , cULus |
Notes | HS Code: 85389091 |
Cross Refefence | Conformity: IEC/EN 61010-1 IEC/EN 61000-6-2 IEC/EN 61000-6-3 UL 508 CSA C22.2 n° 14 |
General characteristics
– Power supply: 7...36VDC
– VAC inputs: Mains L1-L2-L3-N for RGK 900 only
– VAC inputs: Generator L1-L2-L3-N
– Voltage measurement rated value: 600VAC (UL/CSA)
– Voltage measurement range: 30-720VAC
– Frequency measurement range: 45...65Hz or 360...440Hz
– Programmable VT ratio
– Current measurement input (3 PH+N): 0.05-6A or 0.05...1.2A
– Fourth CT for neutral measurement or earth/ground leakage detection
– Graphic LCD, 128x112 pixels with backlight
– 13 digital inputs
– 3 relay outputs rated 8A 250VAC
– 6 static outputs rated 2A, protected
– 1 static output 50mA
– Engine running detection: “D+” generator voltage and frequency
– 1 engine speed input: “W” or “Magnetic Pick-up”
– 3 analog ohmic inputs for oil pressure, engine temperature and fuel level control
– 1 programmable analog input
– 2 analog outputs for engine speed control (governor) / voltage regulator (AVR)
– Alarm-event-parameter text in 5 languages (Web upload)
– Alarm text customisable (16 alarms)
– Event log
– Modbus-RTU, Modbus-ASCII and Modbus-TCP communication protocols
– Boolean logic for inputs, outputs and internal status
– Compatible with Synergy and Xpress software
– Degree of protection: IEC IP65 on front; suitable for use with UL/CSA Type 4X outdoor enclosure installation
– Built-in buzzer
– Multi-level passwords
– Sleep function (power saving mode)
– Synchronising and load sharing.
MAIN FUNCTIONS
– Menus for quick selection of rated parameter settings
– “Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms
– Mains (for RGK 900 only) / Generator controls: Phase sequence, phase loss, max and min voltage and frequency, voltage asymmetry
– Programmable maintenance at various intervals
– Current leakage control towards earth/ground
– Mains-generator synchronising (ATS closed transition)
– Mains in base-load with generator in peak shaving
– Paralleling supervision of generators (island mode)
– Generating set start scheduling.
Certifications and compliance
Certifications obtained: UL Listed for USA and Canada (cULus - File E93601), as Auxiliary Devices, Generator controllers; EAC.
Compliant with standards: IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14.
Synergy and Xpress software, See Section 27.
EXP series expansion modules See Section 28, page 2.