Skip to Main Content »

Search Site
Your shopping cart is empty

All Prices are in Canadian Dollars

Lovato DMK02 - VOLTMETER OR AMMETER - SINGLE PHASE - 1 VOLTAGE OR CURRENT VALUE - 1 MAXIMUM VOLTAGE OR CURRENT VALUE - 1 MINIMUM VOLTAGE OR CURRENT VALUE

Be the first to review this product

Lovato DMK02 - VOLTMETER OR AMMETER - SINGLE PHASE - 1 VOLTAGE OR CURRENT VALUE - 1 MAXIMUM VOLTAGE OR CURRENT VALUE - 1 MINIMUM VOLTAGE OR CURRENT VALUE

 

Availability: In stock

$295.42

/

Additional Information

Brochures & Specific Sheets


Stock Code DMK02
Brand Lovato
UPC 8013975154700
Phase Single Phase
UL Listed EAC , cULus
Notes HS Code: 90303100
Cross Refefence Conformity:
IEC/EN 61010-1
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL508
CSA C22.2 n°14

General characteristics

The DMK 0... instruments are available with flush-mount housing, 96x48mm/3.78x1.89”.
Measurements are True RMS values and provide for reliable operation even in the presence of harmonics.

Operational characteristics

– Auxiliary supply voltage: 220-240VAC;
– Operating frequency: 50-60Hz
– True RMS measurements
– Max. and Min. measurement storage
– 1 relay output with 1 changeover contact (for DMK...R1 only)
– Housing: Flush mount 96x48mm/3.78x1.89”
– Terminals: 4mm2
– Degree of protection: IP54 on front; IP20 at terminals.

DMK 00 - DMK 00 R1
– Voltage measurement range: 15-660VAC
– Operating frequency range: 45-65Hz
– Programmable VT ratio: 1.00-500.00
– Accuracy: ±0.25% f.s. ±1 digit

DMK 01 - DMK 01 R1
– Current measurement range: 0.05-5.75A
– Operating frequency range: 45-65Hz
– Programmable CT ratio: 5-10,000
– Accuracy: ±0.5% f.s. ±1 digit

DMK 02
– Voltage measurement range: 15-660VAC
– Current measurement range: 0.05-5.75A
– Operating frequency range: 45-65Hz
– Programmable VT ratio: 1.00-500.00
– Programmable CT ratio: OFF/5-10,000
– Accuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit

DMK 03 - DMK 03 R1
– Measurement input: 15-660VAC
– Frequency measurement range: 15-65Hz
– Accuracy: ±1 digit

DMK 04 - DMK 04 R1
– Cosphi measurement error: ±0.5° ±1 digit
– Cosphi measurement in 4 quadrants
– Accuracy: ±1° ±1 digit

Control and protection functions

DMK 00 R1
– Voltage loss or failure: OFF/5-85%
– Maximum voltage: OFF/102-120%
– Minimum voltage: OFF/70-98%
– Time delay for max-min voltage or voltage loss, phase loss : 0.0-900.0 seconds.

DMK 01 R1
– Current loss: OFF/2-100%
– Maximum current: OFF/102-200%
– Maximum current instantaneous tripping: OFF/110-600%
– Minimum current: OFF/5-98%
– Time delay for max-min current or current loss : 0.0-900.0 seconds.

DMK 03 R1
– Maximum frequency: OFF/101-110%
– Minimum frequency: OFF/90-99%
– Time delay for min-max frequency : 0.5-900.0 seconds.

DMK 04 R1
– Minimum-maximum cos thresholds in 4 quadrants
– Minimum-maximum PF thresholds in 4 quadrants
– Delay time for max or min threshold : 1-9,000 seconds.

Certifications and compliance

Certifications obtained: EAC; UL Listed, for USA and Canada (cULus - File E93601), as Auxiliary Devices- Multimeters.
Compliant with standards: IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, CSA C22.2 n° 14.

Independent adjustable delays.


Write Your Own Review

Only registered users can write reviews. Please, log in or register

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.