Stock Code | B50-CAN |
---|---|
Brand | Philips |
Family | CSA Certified Emergency Lighting Equipment |
Part No | 511790 |
Length (in) | 13.3" (339mm) |
Width (in) | 2.4" (60mm) |
Height (in) | 1.5" (38mm) |
Voltage (V) | 120/347 VAC, 60 Hz |
Input Current | 280mA |
Wattage (w) | 4.0 Watts |
Bulb Type | Fluorescent Lamps |
Switch Type: | Test Switch: Single Pole |
Lumens (Initial) | 1400 Lumens |
Battery Back Up | Yes |
Battery Type: | High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy |
Recharge Time: | 24 Hrs |
Max. Charge Current | 280mA |
Operates | The B50-CAN can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving. |
Start Temp. (Min) | 0°C (32°F) |
Start Temp. (Max) | 55°C (131°F) |
Weight (lb.) | 3.4 lbs |
UL Listed | UL, CSA and Code Compliance |
Case Quantity | 1 |
Warranty | 5 Years (NOT pro-rata) |
APPLICATION
The B50-CAN fluorescent emergency ballast works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The emergency ballast consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry in one compact red case. The B50-CAN can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving. One- or two-lamp operation may be selected (see Table 1). It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B50-CAN is suitable for indoor locations. It is not suitable for air handling heated air outlets or wet, damp or hazardous locations. For information about specific lamp and ballast compatibility, please call the factory.
OPERATION
When AC power fails, the B50-CAN immediately switches to the emergency mode, operating either one or two lamps at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the B50-CAN automatically returns to the charging mode.
INSTALLATION
The B50-CAN does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B50-CAN may be installed inside, on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C.
cUL, CSA and CODE COMPLIANCE
The B50-CAN has been tested per applicable standards and is cUL Listed and CSA Certified for factory or field installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA-LSC), National Building Code of Canada (NBC), National Fire Code of Canada (NFC) and UL/CSA 90-minute requirements.
B50-CAN
CSA Certified Emergency Lighting Equipment
Specification grade;
One- or two-lamp emergency
illumination
Product Summary
-
cUL LISTED/CSA CERTIFIEDFactory or Field Installation
-
Illumination Time90 Minutes
-
Initial Light Output1100 - 1400 Lumens
-
Full Warranty5 Years (NOT pro-rata)
-
Voltage120/347 VAC, 60 Hz
-
AC Input Current280 mA
-
AC Input Power Rating4.0 Watts
-
Test SwitchSingle Pole
-
BatteryHigh-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy -
Battery Charging Current280 mA
-
Recharge Time24 Hour
-
Charging Indicator LightLED
-
Temperature Rating (Ambient)0°C to +50°C (32°F to 122°F)
-
Dimensions13.3" x 2.4" x 1.5"
(339 mm x 60 mm x 38 mm)
Mounting Center 12.8" (325 mm) -
Weight3.4 lbs. (1.54 kg)