Additional Information
Stock Code | B50LP |
---|---|
Brand | Philips |
Family | Flourescent Emergency Ballast, Low-Profile for Space-Limited Fixtiures |
Length (in) | 21.5" (546mm) |
Width (in) | 1.18" (30mm) |
Height (in) | 1.18" (30mm) |
Voltage (V) | 120/277VAC, 60Hz |
Input Current | 200mA |
Wattage (w) | 4.0 Watts |
Bulb Type | Fluorescent Lamps |
Switch Type: | Test Switch: Single Pole |
Lumens (Initial) | 1300 Lumens |
Battery Back Up | Yes |
Battery Type: | High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy |
Recharge Time: | 24 Hrs |
Max. Charge Current | 180mA |
Operates | The B50LP can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving fluorescent lamps |
Start Temp. (Min) | 0°C (32°F) |
Start Temp. (Max) | 50°C (122°F) |
Weight (lb.) | 3.3 lbs |
UL Listed | UL and Code Compliance |
Case Quantity | 1 |
Warranty | 5 Years (NOT pro-rata) |
APPLICATION
The B50LP low-profile emergency ballast works in conjunction with a low-profile or standard-size AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting. The emergency ballast consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry in one compact case. The B50LP can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving fluorescent lamps. One- or two-lamp operation may be selected (see Table 1). It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B50LP is suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations. It is not suitable for air handling heated air outlets or wet or hazardous locations. For information about specific lamp and ballast compatibility, please contact the factory. Recommended applications include: emergency lighting for pendant, cove, recessed indirect/direct, surface-mount and architectural lighting commonly used in office, hospitality, health care, retail and educational facilities.
OPERATION
When AC power fails, the B50LP automatically switches to emergency power, operating one or two lamps at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.
INSTALLATION
The B50LP does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B50LP may be installed inside, on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C.
EMERGENCY ILLUMINATION
Depending on the number (one or two), wattage and type of lamps selected, the B50LP produces 750 to 1300 lumens initial emergency light output (see Table 2). If two-lamp operation is selected, light output is evenly divided between the lamps for better distribution of emergency illumination.
B50LP
Low-Profile Emergency Lighting Equipment
Specification grade;
High lumen, low profile
End-of-lamp-life compatible
Product Summary
-
UL ListedFactory or Field Installation
(Indoor and Damp) -
Illumination Time90 Minutes
-
Initial Light Output750 - 1300 Lumens
-
Full Warranty5 Years (NOT pro-rata)
-
Dual Input Voltage120/277 VAC, 60 Hz
-
AC Input Current200 mA
-
AC Input Power Rating4.0 Watts
-
Test SwitchSingle Pole
-
BatteryHigh-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy -
Battery Charging Current180 mA
-
Recharge Time24 Hour
-
Charging Indicator LightLED
-
Temperature Rating (Ambient)0°C to +50°C (32°F to 122°F)
-
Dimensions21.5" x 1.18" x 1.18"
(546 mm x 30 mm x 30 mm)
Mounting Center 21.1" (536 mm) -