Philips Bodine B50LP - Emergency Ballast - 90 Min. - Operates (1) or (2) T8, T9, T10, T12 Fluoresent Lamps - Dual Voltage 120/277V

Be the first to review this product

The B50LP can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving fluorescent lamps. One- or two-lamp operation may be selected (see Table 1). It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary


When AC power fails, the B50LP automatically switches to emergency power, operating one or two lamps at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.

 

Availability: In stock

$219.99

Philips Bodine B50LP - Emergency Ballast - 90 Min. - Operates (1) or (2) T8, T9, T10, T12 Fluoresent Lamps - Dual Voltage 120/277V

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code B50LP
Brand Philips
Family Flourescent Emergency Ballast, Low-Profile for Space-Limited Fixtiures
Length (in) 21.5" (546mm)
Width (in) 1.18" (30mm)
Height (in) 1.18" (30mm)
Voltage (V) 120/277VAC, 60Hz
Input Current 200mA
Wattage (w) 4.0 Watts
Bulb Type Fluorescent Lamps
Switch Type: Test Switch: Single Pole
Lumens (Initial) 1300 Lumens
Battery Back Up Yes
Battery Type: High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy
Recharge Time: 24 Hrs
Max. Charge Current 180mA
Operates The B50LP can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving fluorescent lamps
Start Temp. (Min) 0°C (32°F)
Start Temp. (Max) 50°C (122°F)
Weight (lb.) 3.3 lbs
UL Listed UL and Code Compliance
Case Quantity 1
Warranty 5 Years (NOT pro-rata)

APPLICATION

The B50LP low-profile emergency ballast works in conjunction with a low-profile or standard-size AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting. The emergency ballast consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry in one compact case. The B50LP can be used with most 17 - 215 W (2’ - 8’) T8, T9, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving fluorescent lamps. One- or two-lamp operation may be selected (see Table 1). It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B50LP is suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations. It is not suitable for air handling heated air outlets or wet or hazardous locations. For information about specific lamp and ballast compatibility, please contact the factory. Recommended applications include: emergency lighting for pendant, cove, recessed indirect/direct, surface-mount and architectural lighting commonly used in office, hospitality, health care, retail and educational facilities.

OPERATION

When AC power fails, the B50LP automatically switches to emergency power, operating one or two lamps at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.

INSTALLATION

The B50LP does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B50LP may be installed inside, on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C.

EMERGENCY ILLUMINATION

Depending on the number (one or two), wattage and type of lamps selected, the B50LP produces 750 to 1300 lumens initial emergency light output (see Table 2). If two-lamp operation is selected, light output is evenly divided between the lamps for better distribution of emergency illumination.

 

B50LP

Low-Profile Emergency Lighting Equipment


Specification grade;
High lumen, low profile
End-of-lamp-life compatible

 

Product Summary

  • UL Listed
    Factory or Field Installation
    (Indoor and Damp)
  • Illumination Time
    90 Minutes
  • Initial Light Output
    750 - 1300 Lumens
  • Full Warranty
    5 Years (NOT pro-rata)
  • Dual Input Voltage
    120/277 VAC, 60 Hz
  • AC Input Current
    200 mA
  • AC Input Power Rating
    4.0 Watts
  • Test Switch
    Single Pole
  • Battery
    High-Temperature, Maintenance-Free
    Nickel-Cadmium Battery
    7- to 10-Year Life Expectancy
  • Battery Charging Current
    180 mA
  • Recharge Time
    24 Hour
  • Charging Indicator Light
    LED
  • Temperature Rating (Ambient)
    0°C to +50°C (32°F to 122°F)
  • Dimensions
    21.5" x 1.18" x 1.18"
    (546 mm x 30 mm x 30 mm)
    Mounting Center 21.1" (536 mm)
  • Weight
    3.3 lbs. (1.5 kg)