Bodine 197921 B100ELC - Emergency Ballast - 90 Min. - Operates (1) x 32-40W T8, T10, T12 or PLL CFL - 120V

Be the first to review this product

B100 available only as as ELC (end-of-lamp-life compatible). One 17-215 W (2’- 8’) T8, T10 or T12 lamp or one (4-pin) long compact. Not recommended with reduced-wattage, energy-saving T8 lamps.


When AC power fails, the B100 immediately switches to the emergency mode, operating one lamp at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.

 

Availability: In stock

$103.12

Bodine 197921 B100ELC - Emergency Ballast - 90 Min. - Operates (1) x 32-40W T8, T10, T12 or PLL CFL - 120V

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Additional Information

Brochures & Specific Sheets


Stock Code Bodine_B100ELC
Brand Philips
Family CSA Certified Emergency Lighting Equipment
Part No 197921
Length (in) 9.4" (238mm)
Width (in) 2.4" (60mm)
Height (in) 1.5" (38mm)
Voltage (V) 120/277V, 60Hz
Input Current 280mA
Wattage (w) 2.5 Watts
Bulb Type Fluorescent Lamps
Switch Type: Test Switch: Single Pole
Lumens (Initial) 450 Lumens
Battery Back Up Yes
Battery Type: High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy
Recharge Time: 24 Hrs
Max. Charge Current 280mA
Operates One 17-40 W (2’- 4’) T8, T10 or T12 lamp or one (4-pin) long compact. Not recommended with reduced-wattage, energy-saving T8 lamps
Start Temp. (Min) 0°C (32°F) / Dry and Damp Location
Start Temp. (Max) 50°C (122°F) (Damp Location) / 55°C (131°F) (Dry Location) /
Weight (lb.) 2.1 lbs
UL Listed UL, CSA and Code Compliance
Case Quantity 1
Warranty 1 Years (NOT pro-rata)

APPLICATION

The B100 emergency ballast works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The emergency ballast consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry. The B100 can be used with most 32 - 40 W (2’ - 4’) T8, T10, or T12 fluorescent lamps without an integral starter, including U-shaped, HO, VHO, circline and energy-saving. It is also compatible with most one-, two-, three- and fourlamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B100 is suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations. It is not suitable for air handling heated air outlets or wet or hazardous locations. For information about specific lamp and ballast compatibility, please call the factory.

OPERATION

When AC power fails, the B100 immediately switches to the emergency mode, operating one lamp at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.

INSTALLATION

The B100 does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B100 may be installed inside, on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C.

EMERGENCY ILLUMINATION

Depending on the wattage and type of lamp selected, the B100 produces 350 to 450 lumens initial emergency light output. During emergency illumination, one lamp is illuminated, even if installed with a multi-lamp AC ballast. Emergency lumen output will be less with a compact fluorescent lamp.

SPECIFICATION

Emergency lighting shall be provided by using a standard fluorescent fixture equipped with a Philips Bodine B100 emergency ballast. This emergency ballast shall consist of a high-temperature, maintenancefree nickel-cadmium battery, charger and electronic circuitry contained in one 9 3/8” x 2 3/8” x 1 1/2” red metal case. A solid-state charging indicator light to monitor the charger and battery, a single-pole test switch and installation hardware shall be provided. The emergency ballast, using a patented circuit, shall delay AC ballast operation for approximately three seconds to prevent false tripping of AC ballast end-of-lamp-life shutdown circuits. The emergency ballast shall be capable of operating one 32 - 40 W (2’ - 4’) T8, T10 or T12 fluorescent lamp at reduced illumination in the emergency mode for a minimum of 90 minutes. It shall be suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations. The B100 shall produce 350 to 450 lumens initial emergency light output, have 3.5 Watts of input power and a 9.6 Watt-hour battery capacity and comply with emergency standards set forth by the current NEC. The emergency ballast shall be UL Listed for installation inside, on top of or remote from the fixture and shall be warranted for a full year from date of purchase.

 

B100

CSA Certified Emergency Lighting Equipment


For Damp locations; 
Convenient code compliance; 
End-of-lamp-life compatible

 

Product Summary

  • UL Listed
    Factory or Field Installation (Damp)
  • Illumination Time
    90 Minutes
  • Initial Light Output
    350 - 450 Lumens
  • Full Warranty
    1 Year (NOT pro-rata)
  • Dual Input Voltage
    120/277 VAC, 60 Hz
  • AC Input Current
    280 mA
  • AC Input Power Rating
    2.5 Watts
  • Test Switch
    Single Pole
  • Battery
    High-Temperature, Maintenance-Free
    Nickel-Cadmium Battery
    7- to 10-Year Life Expectancy
  • Battery Charging Current
    280 mA
  • Recharge Time
    24 Hour
  • Charging Indicator Light
    LED
  • Temperature Rating (Ambient)
    Damp Location
    0°C to +50°C
    (32°F to 122°F)

    Dry Location
    0°C to +55°C
    (32°F to 131°F)
  • Dimensions
    9.4" x 2.4" x 1.5"
    (238 mm x 60 mm x 38 mm)
    Mounting Center 8.9" (226 mm)
  • Weight
    2.1 lbs. (.95 kg)