Additional Information
Stock Code | B33 |
---|---|
Brand | Philips |
Family | CSA Certified Emergency Lighting Equipment |
Part No | 197517 |
Length (in) | 16.3" (414mm) |
Width (in) | 5.5" (138mm) |
Height (in) | 1.7" (44mm) |
Voltage (V) | 120/277V, 60Hz |
Input Current | 280mA |
Wattage (w) | 8.0 Watts |
Bulb Type | Fluorescent Lamps |
Switch Type: | Test Switch: Single Pole |
Lumens (Initial) | 3400 Lumens |
Battery Back Up | Yes |
Battery Type: | High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy |
Recharge Time: | 24 Hrs |
Max. Charge Current | 280mA |
Operates | The B33 can be used with two or three 32 W (4’) T8 fluorescent lamps without integral starters. It is compatible ONLY with instant start, parallel two-, three- or four-lamp electronic or standard AC ballasts. |
Start Temp. (Min) | 5°C (41°F) |
Start Temp. (Max) | 50°C (122°F) |
Weight (lb.) | 8.7 lbs |
UL Listed | UL, CSA and Code Compliance |
Case Quantity | 1 |
Warranty | 5 Years (NOT pro-rata) |
Notes | It is compatible ONLY with instant start, parallel two-, three- or four-lamp electronic or standard AC ballasts |
APPLICATION
The B33 emergency ballast works in conjunction with an INSTANT START, PARALLEL AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The emergency balast consists of a nickel-cadmium battery, charger and electronic circuitry. The B33 can be used with two or three 32 W (4’) T8 fluorescent lamps without integral starters. It is compatible ONLY with instant start, parallel two-, three- or four-lamp electronic or standard AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B33 is suitable for indoor and damp locations. It is not suitable for air handling heated air outlets or wet or hazardous locations. For information about specific lamp and ballast compatibility, please call the factory. Recommended applications include: hospital surgical suites, areas along the path of egress with high ceiling heights and health care, educational, commercial and institutional facilities needing higher levels of emergency illumination.
OPERATION
When AC power fails, the B33 immediately switches to the emergency mode, operating either two or three lamps for a minimum of 90 minutes. When AC power is restored, the B33 automatically returns to the charging mode.
INSTALLATION
The B33 does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B33 may be installed on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below +5°C. A charging indicator light and single-pole test switch are provided. Upon request, a single-pole test switch/ monitor plate is provided for remote installation of the test switch and charging indicator. (fits single-gang box)
EMERGENCY ILLUMINATION
The B33 has been optimized for three-lamp operation. The B33 produces 3250 to 3400 lumens initial emergency light output with three 32 W (4’) T8 lamps. Total light output is evenly divided among the lamps for better distribution of emergency illumination.
B33
UL and CSA Certified Emergency Lighting Equipment
Specification-grade, three-lamp parallel emergency illumination; 3400 lumens with three 32 W (4') T8 lamps
Product Summary
-
UL ListedFactory or Field Installation
-
Illumination Time90 Minutes
-
Initial Light Output2700 - 3400 Lumens
-
Full Warranty5 Years (NOT pro-rata)
-
Voltage120/277 VAC, 60 Hz
-
AC Input Current280 mA
-
AC Input Power Rating8.0 Watts
-
Test SwitchSingle Pole
-
BatteryHigh-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy -
Battery Charging Current280 mA
-
Recharge Time24 Hour
-
Charging Indicator LightLED
-
Temperature Rating (Ambient)+5°C to +50°C (41°F to 122°F)
-
Dimensions16.3" x 5.5" x 1.7"
(414 mm x 138 mm x 44 mm)
2' (610 mm) Flexible Conduit
Mounting Center 15.7" (400 mm) -
Weight8.7 lbs. (3.9 kg)
![]()